Tank Disinfection Setting 1; Tank Disinfection Setting 2 - LG THERMA V HN0916T Installation Manual

Air-to-water heat pump
Table of Contents

Advertisement

Tank disinfection setting 1, 2

• Disinfection operation is special DHW tank operation mode to kill and to prevent growth of
legionella inside the tank.
- Disinfection active : Selecting enable or disable of disinfection operation.
- Start date : Determining the date when the disinfection mode is running.
- Start time : Determining the time when the disinfection mode is running.
- Max temp. : Target temperature of disinfection mode.
- Duration time : Duration of disinfection mode.
Water temperature
NOTE
DHW heating should be enable
• If Disinfection active is set as ' Not use', that is 'disable disinfection mode', Start date and
Start time is not used.
(Inside DHW)
Max temp
Duration time
Start time
OK
OK
INSTALLER SETTING
Temperature profile
of Disinfection operation
Time
141