INSTRUCTION MANUAL
SPECIFICATIONS
Power Supply:
230–240V ~ 50Hz
Motor:
1200W (S3, 50%), 1.6HP
Tank Capacity:
40L
No Load Speed:
2,850/min
Max. Pressure:
8bar (116psi)
Max. Flow Rate:
165L/min
Free Air Delivery: 105L/min
IP Rating:
IP20
Weight:
24kg
ozito.com.au
IN ORDER TO MAKE A CLAIM UNDER THIS
WARRANTY YOU MUST RETURN THE PRODUCT
TO YOUR NEAREST BUNNINGS WAREHOUSE WITH
YOUR BUNNINGS REGISTER RECEIPT. PRIOR TO
RETURNING YOUR PRODUCT FOR WARRANTY
PLEASE TELEPHONE OUR CUSTOMER SERVICE
HELPLINE:
Australia 1800 069 486
New Zealand 0508 069 486
TO ENSURE A SPEEDY RESPONSE PLEASE
HAVE THE MODEL NUMBER AND DATE OF
PURCHASE AVAILABLE. A CUSTOMER SERVICE
REPRESENTATIVE WILL TAKE YOUR CALL
AND ANSWER ANY QUESTIONS YOU MAY
HAVE RELATING TO THE WARRANTY POLICY
OR PROCEDURE.
OZITO
Australia/New Zealand (Head Office) 1-23 Letcon Drive, Bangholme, Victoria, Australia 3175.
WARRANTY
The benefits provided under this warranty are in addition
to other rights and remedies which are available to you at law.
Our goods come with guarantees that cannot be excluded
at law. You are entitled to a replacement or refund for a major
failure and for compensation for any other reasonably foreseeable
loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure.
Generally you will be responsible for all costs associated with
a claim under this warranty, however, where you have suffered
any additional direct loss as a result of a defective product you
may be able to claim such expenses by contacting our customer
service helpline above.
3 YEAR REPLACEMENT WARRANTY
Your product is guaranteed for a period of 36 months from
the original date of purchase. If a product is defective it will
be replaced in accordance with the terms of this warranty.
Warranty excludes consumable parts, for example: valve adapters
and accessories.
WARNING
The following actions will result in the warranty being void.
• If the tool has been operated on a supply voltage other
than that specified on the tool.
• If the tool shows signs of damage or defects caused
by or resulting from abuse, accidents or alterations.
• Failure to perform maintenance as set out within the
instruction manual.
• If the tool is disassembled or tampered with in any way.
• Professional, industrial or high frequency use.
STANDARD EQUIPMENT
Air Compressor
(5)00
6
4
(5)00
PRESSURE GAUGE
(7)00
4
6
(3)00
PRESSURE GAUGE
(7)00
(3)00
8
8
2
2
(9)00
(9)00
(1)00
(1)00
10
10
0
0
kg/cm²
kg/cm²
kPA
Lb/in²
(BAR)
(PSI)
kPA
Lb/in²
(BAR)
(PSI)
2 x Wheels, 2 x Wheel Covers, 2 x
M10 Bolts, 2 x Large Washers, 2 x
Large Spring Washers & 2 x M10
Nuts
Air Filter, Breather Plug,
Supporting Foot, M6 Bolt, 2 x
Small Washers, Small Spring
Washer & M6 Nut
(5)00
PRESSURE GAUGE
4
(7)00
6
4
(5)00
(7)00
6
2
(3)00
8
(3)00
PRESSURE GAUGE
8
(9)00
2
(9)00
(1)00
10
(1)00
0
kg/cm²
10
0
kg/cm²
kPA
Lb/in²
kPA
(BAR)
Lb/in²
(PSI)
(BAR)
(PSI)
ACP-4020
0920

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACP-4020 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ozito ACP-4020

  • Page 1 Supporting Foot, M6 Bolt, 2 x Small Washers, Small Spring Washer & M6 Nut ACP-4020 WARRANTY IN ORDER TO MAKE A CLAIM UNDER THIS The benefits provided under this warranty are in addition to other rights and remedies which are available to you at law.
  • Page 2: Know Your Product

    KNOW YOUR PRODUCT SETUP & PREPARATION AIR COMPRESSOR 1. ASSEMBLY 1. Motor Housing 10. Drain Valve 2. On/Off Button 11. Wheels 3. Tank Pressure Gauge 12. Safety Relief Valve WARNING! ENSURE THE TOOL IS TURNED OFF 4. Pressure Regulator 13. Intake Air Filter AND DISCONNECTED FROM THE POWER SUPPLY 5.
  • Page 3: Operation

    OPERATION 2. CONTROLS Fitting The Air Filter WARNING! THE AIR COMPRESSOR MUST BE USED WITH A RESIDUAL CURRENT DEVICE WITH A 1. Remove the transportation RATED RESIDUAL CURRENT OF 30MA OR LESS. cover from the air filter connection with a screwdriver. WARNING! DO NOT LEAVE THE AIR COMPRESSOR UNATTENDED WHILE THE ON/OFF SWITCH IS IN...
  • Page 4 3. USAGE Adjusting The Output Pressure WARNING! BEFORE CONNECTING THE The output pressure of the regulated pressure outlet can be adjusted COMPRESSOR TO THE POWER SOURCE, CHECK to suit the air tool connected and the task at hand. FOR BROKEN COMPONENTS AND ACCESSORIES. ALSO CHECK FOR DAMAGE TO THE HOSE.
  • Page 5: Troubleshooting

    THROUGH THE AIR AT HIGH PRESSURE. 6. When no more air is released, open the drain valve to release any accumulated liquid from the tank. 7. Close the drain valve, allow the compressor to cool down, then clean and store the unit. ACP-4020...
  • Page 6: Maintenance

    Note: The tank will not pressurise while the drain valve is open. required level (approximately 200ml). Ozito compressor oil or SAE 15W/40 oil or an alternative of the same quality is recommended.
  • Page 7: Description Of Symbols

    Please recycle where facilities exist. Check Note: Ozito Industries will not be responsible for any damage or with your local council authority for recycling advice. injuries caused by the repair of the tool by an unauthorised person or by mishandling of the tool.
  • Page 8: Electrical Safety

    ELECTRICAL SAFETY WARNING! Note: The supply of 230V and 240V on Ozito tools are interchangeable for Australia and New Zealand. When using mains-powered tools, basic safety precautions, including the following, should always be followed to reduce risk of fire, electric shock, personal injury and Note: Double insulation does not take the place of normal safety precautions when operating this tool.