Start-Up Checklist - Carrier Omnizone 09XC06 Installation, Start-Up And Service Instructions Manual

Remote air-cooled condenser units
Table of Contents

Advertisement

NOTE: To avoid injury to personnel and damage to equipment or
property when completing the procedures listed in this start-up
checklist, use good judgment, follow safe practices, and adhere
to the safety considerations/information as outlined in preceding
sections of this Installation, Start-Up, and Service document.
I. PRELIMINARY INFORMATION
MODEL NO. ____________________
09XC UNIT:
FIELD-INSTALLED ACCESSORIES: _____________________________________________________________________
START-UP DATE: ______________________________________
II. PRE-START-UP:
VERIFY ALL SHIPPING MATERIALS HAVE BEEN REMOVED FROM THE UNIT
IS THERE ANY SHIPPING DAMAGE? ________________ IF SO, WHERE ________________
_____________________________________________________________________________________________________
WILL THIS DAMAGE PREVENT UNIT START-UP?
CHECK POWER SUPPLY. DOES IT AGREE WITH UNIT?
HAS THE GROUND WIRE BEEN CONNECTED?
HAS THE CIRCUIT PROTECTION BEEN SIZED AND INSTALLED PROPERLY?
ARE THE POWER WIRES TO THE UNIT SIZED AND INSTALLED PROPERLY?
HAVE CONDENSER FAN AND MOTOR PULLEYS BEEN CHECKED FOR PROPER
ALIGNMENT AND DO THE FAN BELTS HAVE PROPER TENSION?
HAS CORRECT FAN ROTATION ON CONDENSER BEEN CONFIRMED?
ARE PROPER AIR FILTERS IN PLACE AND ARE FILTERS CLEAN?
VERIFY UNIT IS INSTALLED WITHIN LEVELING TOLERANCES
CONTROLS
HAVE CONTROL CONNECTIONS BEEN MADE AND CHECKED?
ARE ALL WIRING TERMINALS (including main power supply) TIGHT?
PIPING
HAVE LEAK CHECKS BEEN MADE AT COMPRESSOR, CONDENSER, EVAPORATOR, TXVs
(Thermostatic Expansion Valves), SOLENOID VALVES, FILTER DRIERS, AND FUSIBLE PLUGS
WITH A LEAK DETECTOR? (Y/N) _______
LOCATE, REPAIR, AND REPORT ANY LEAKS
HAVE ALL COMPRESSOR SERVICE VALVES BEEN FULLY OPENED (BACKSEATED)? (Y/N) _______
HAVE LIQUID LINE SERVICE VALVES BEEN OPENED? (Y/N) _______
IS THE OIL LEVEL IN THE COMPRESSOR CRANKCASE ON THE UNIT IN VIEW IN THE
COMPRESSOR SIGHT GLASS (IF APPROPRIATE)? (Y/N) _______
HAS CONDENSER PRESSURE RELIEF BEEN PROVIDED? (Y/N) _______
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53090029-01

START-UP CHECKLIST

(Fill out this form on Start-Up and file in job folder)
Printed in U.S.A.
Form 09XC-5SI
SERIAL NO. ____________________
(Y/N) _______
(Y/N) _______
(Y/N) _______
(Y/N) _______
(Y/N) _______
(Y/N) _______
(Y/N) _______
(Y/N) _______
(Y/N) _______
Pg CL-1
(Y/N) _______
(Y/N) _______
11-20
Replaces: 09XC-4SI