KaWe SwiSto3 User Manual

KaWe SwiSto3 User Manual

Iontophoresis device for home and clinical use
Hide thumbs Also See for SwiSto3:

Advertisement

Quick Links

User's Manual
SwiSto3 iontophoresis device for home and clinical use
Treatment time
Continuous current
or pulsed current
Positive polarity anode
Graphical display of the
treatment amperage
Increase the intensity of the
current / change type of current /
increase treatment time
Decrease the intensity of the
current / change type of current /
increase treatment time
A
C
F
D
B
240 V
E
EU
VERSION
G
16
Negative polarity cathode
to navigate through the menu,
SwiSto3 – iontophoresis set
for the treatment of hand and foot perspiration
Scope of delivery:
1 SwiSto3 – iontophoresis device
A
1 charging plug
B
2 water trays
C
2 electrode plates incl. cable
D
2 foam pads
E
Special accessories
for underarm perspiration treatment
Plate electrodes with sponge pockets
F
Replacement sponge pockets
G
Charge level of the
Li-ion rechargeable
battery
Display of the treatment
amperage
Power button
Button function:
Menu/Set/Stop
to stop treatment

Advertisement

Table of Contents
loading

Summary of Contents for KaWe SwiSto3

  • Page 1 User's Manual SwiSto3 iontophoresis device for home and clinical use Treatment time Charge level of the Continuous current Li-ion rechargeable or pulsed current battery Positive polarity anode Negative polarity cathode Graphical display of the Display of the treatment treatment amperage...
  • Page 2: Table Of Contents

    2 x plate electrodes with sponge pockets for underarm perspiration 1. Application The SwiSto3 is used in medical facilities and in the home by healthcare treatment, 2 x replacement sponge pockets (ca. 90 x 110 mm) alone professionals as well as by non-professionals.
  • Page 3: Contraindications/Side Effects And Preventative Measures

    Nevertheless, • Only use standard accessories provided by KaWe. The use of other while using pulsed current, slight stinging, burning or tingling sen- cables, charging devices, electrodes, water trays etc. is not allowed.
  • Page 4: Start-Up/Preparation

    • To charge the battery, first plug the low-voltage connector into the • If the treatment is intentionally performed with a very high electric socket on the back side of the unplugged SwiSto3 SwiSto3 ionto- current, an uncomfortable tingling can occur in the extremities phoresis device.
  • Page 5: Treatment Of Underarm Perspiration

    When the current is being changed during the treatment, the current reading on the • The SwiSto3 iontophoresis device can also be plugged into the local display does not blink. WARNING: Do not exceed the recommended power supply network to be charged using the charging plug. The maximum current intensity of 5 mA.
  • Page 6: Important Information

    12.2 Treatment is interrupted – possible causes • Disruption of the treatment circuit – such as by suddenly removing • The SwiSto3 iontophoresis device can also be plugged into the local hands/feet from the trays or raising your arm during an underarm power supply network to be charged using the charging plug.
  • Page 7: Cleaning And Disinfection

    If corroded, the ca- must not change. bles are to be replaced. If the contact plugs on the SwiSto3 become corroded, send the device in for inspection. When the DOWN button is pressed, the current intensity output of the device gradually diminishes.
  • Page 8: Technical Information

    20. Guidance and manufacturer’s declaration – electromagnetic emmisions The SwiSto3 is designed to be used in the types of electromagnetic environments listed below. The customer or user is responsible for ensuring that this device is used in such an environment.
  • Page 9: Guidance And Manufacturer's Declaration

    Guidance and Manufacturer’s Declaration – Electromagnetic Immunity The SwiSto3 is intended for use in the electromagnetic environment specified below. The customer or user is to assure that it is used in such an environment. Immunity test IEC 60601 Compliance level Electromagnetic environment –...
  • Page 10 Guidance and Manufacturer’s Declaration – Electromagnetic Immunity The SwiSto3 is intended for use in the electromagnetic environment specified below. The customer or user of the SwiSto3 is to assure that it is used in such an environment. IEC 60601 Compliance Immunity test Electromagnetic environment –...
  • Page 11: Recommended Separation Distances Between Portable And

    21. Recommended separation distances between portable and mobile RF communications equipment and the SwiSto3 The SwiSto3 is intended for use in the electromagnetic environment described below. The customer or the user of the SwiSto3 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the SwiSto3 as recommended below, according to the maximum output power of the communications equipment.