Sound level meter

Advertisement

4.7.9.
To exit SET UP mode and save your settings press HOLD once.
4.7.9.1.
If you continue to press the A/C button in edit mode the initialization/reset screen appears. If you now press the A/C button again your personal
settings will be lost and the screen reverts to the original factory settings.
5. OPERATION
WARNING: In strong wind conditions it is essential that the wind muffler is used to avoid picking up unnecessary background
noise, see fig.3 below.
5.1.
Switch the meter on by pressing the ON/OFF button.
5.2.
Press the LEVEL/REC button up to four times to cycle through to the best level for the measurement task in hand. Keep an eye on the
OVER and UNDER indicators at the top of the LCD display. Select a level where these indicators are off.
5.3.
Using the A/C button select 'dBA' for recording general sound levels in relation to human hearing and 'dBC' for measuring the sound
level of general acoustic material.
5.4.
Using the F/S button select either FAST sampling for instant sound and SLOW sampling for average sound level.
5.5.
Using the MAX/MIN button select whether you require to monitor the maximum sound level predominant at the time of measuring or
the minimum sound level.
5.6.
Begin measuring sound levels by either using the unit held in your hand or mount it on a tripod. The meter should be 1 to 1.5 metres
away from the sound source.
5.7.
Record sound levels as required as described in Data Reading Function section.
6. MAINTENANCE
DO NOT store or operate the meter at high temperature or in conditions of high humidity.
8
6.1.
If the meter is not to be used for long periods of time, remove the battery to avoid harmful liquid leakage.
6.2.
Keep microphone dry and avoid severe vibration.
6.3.
When the battery symbol shows on the readout replace the 9V battery (PP9).
.
BATTERY REMOVAL
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products
containing batteries (as defined within these regulations), that they are registered with Valpak's registered compliance scheme. Jack
Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
01284 703534
sales@sealey.co.uk
Original Language Version
www.sealey.co.uk
TA060 Issue:2 (H,F) 08/12/20

Advertisement

loading