American Dynamics RJ856UD Series Installation Manual
American Dynamics RJ856UD Series Installation Manual

American Dynamics RJ856UD Series Installation Manual

Rs-422 single-position junction box (j-box)
Hide thumbs Also See for RJ856UD Series:

Advertisement

Quick Links

RS-422 Single-Position
Junction Box (J-Box)

Installation Guide

Figure 1. RS-422 J-Box
Cover Retaining
Screws, Plastic (4)
Spare
Fuses (2)
Access for Cables
from Host and Dome
RJ856UD and RJ856UD-1 Series
This weather-tight box (Figure 1) provides Class 2
LPS power and data to the new SpeedDome Ultra
outdoor camera housing.
IMPORTANT: Read Regulatory Requirements
and other declarations on page 8.
© 2006 Sensormatic Electronics Corp.
RS-422 SINGLE-POSITION JUNCTION BOX (J-BOX)
INSTALLATION GUIDE
On/Off Switch
Latches (2)
1 of 10

IMPORTANT SAFEGUARDS

The J-box is a 10A, 2 pole, ganged disconnect
device, which also provides short circuit and
overload protection, and has a minimum 3mm
open circuit clearance, in accordance with the
National Electric Code and applicable local codes
must be installed at a location readily accessible to
the equipment.
(Ein 10A, 2-poliges, gekoppeltes Ausschaltgerät,
welches auch über einen Kurzschluß- sowie
Überbelastungsschutz verfügt, und einen
minimum 3mm offenen Schaltabstand aufweist,
nach Übereinstimmung mit den Nationalen
Elektrischen Regelungen sowie lokalen Regeln,
muß an einem Standort installiert werden, welcher
einfachen Zugang zum Gerät erlaubt.)
Outside elements: To keep outside elements
from entering the J-box, always mount it vertically
with cable exits facing down, and tighten the four
plastic screws.
Adding access holes to the enclosure. The
J-box meets the NEMA 4 standard for
weatherproofing. To maintain this rating, make
sure any hole you drill in the enclosure is
thoroughly sealed with silicone-based RTV
compound.
Switching to 240Vac: If using 240Vac to drive the
J-box, you must change jumper terminations on
the primary winding of transformer. Refer to label
inside cover of J-box.
Approved power cords: Use only regulatory-
approved polarized power cords.
Socket-outlet: For installation using a line cord,
the socket-outlet must be installed near the
equipment and at an easily accessible location.
(Für Installationen mit einem Stromkabel muß die
Steckdose an einem Standort installiert werden,
welcher einfachen Zugang erlaubt.)
This product does not support Manchester
protocol: It will support RS-422.
USE ONLY WITH American Dynamics products
and other approved products from
Sensormatic Electronics Corporation.
See inside for additional safeguards.
8000-2573-20, REV. H

Advertisement

Table of Contents
loading

Summary of Contents for American Dynamics RJ856UD Series

  • Page 1: Important Safeguards

    Steckdose an einem Standort installiert werden, welcher einfachen Zugang erlaubt.) This product does not support Manchester protocol: It will support RS-422. USE ONLY WITH American Dynamics products and other approved products from Sensormatic Electronics Corporation. See inside for additional safeguards.
  • Page 2: Product Codes

    RS-422 Single-Position J-Box Specifications REG ID: SV JBOX1 Product Codes RJ856UD ...120V with North American line cord RJ856UD-1 ...230V with Continental European line cord Transformer primary jumpers and mains line cord are field changeable to support either 120Vac or 230Vac Electrical Power source ...100–120Vac or 200–...
  • Page 3 Mounting the J-Box This section explains how to mount the J-box to a wall or pole. Parts Required Installation Kit (0351-1646-01) includes: Item Screw, Self-tapping, 4.8x25, PHP Anchor Bolt, ¼-20x2¼, w/Hardware Anchor, Toggle, Nylon, #8-#10 Screw CAUTION: Before you begin, do the following: −...
  • Page 4 (Figure 4b). Then turn screw just enough to engage rack. Prepare two racks this way. 2. As shown in Figure 4c, with J-box on ground and its rear facing towards you: a. Slip one of the two bands through closed slots in lower mounting bracket.
  • Page 5: Connecting Ac Power

    Connecting AC Power The J-box comes wired for 120Vac and has a 2m (6ft-7in) SJT 3-conductor power cord attached. Plug the cord into a dedicated 24-hour, unswitched outlet. If the box is to be driven by 240Vac, then the power cord (if used) and jumpers across the primary winding of the transformer within the box will have to be changed (Figure 6).
  • Page 6: Connecting Power And Data Cables

    Wires within the data cable are organized in two polarized 22AWG, shielded, twisted pairs. Up to 1km (3000ft) of data cable can be run from the Host to the J-box, or from J-box to J-box (see CAUTION below). For more information about the RS-422 communication protocol and possible cable network configurations, see Communication Protocols and Cable Networks, 8000-2573-19.
  • Page 7 Blinking red, Green off Both LEDs off DS2 flashes red for each dome that answers through J-box. It takes up to 1 minute for DS2 to flash when only one dome is connected to the J-box. 7 of 10 Data Test Switch S1 Comm.
  • Page 8: Troubleshooting

    1. Loosen four captive screws to release cover. 2. Remove six screws to remove circuit board (Figure 10). Figure 10. Screws (6) RS-422 SINGLE-POSITION JUNCTION BOX (J-BOX) INSTALLATION GUIDE Removing the Transformer Follow steps to remove the transformer. Reverse steps to reassemble.
  • Page 9: Ordering Parts

    • Power Transformer 5604-0205-01 • Cable Strain Relief 3100-0035-11 • Fuse 5111-0017-21. These parts are shown bold in Figure 13. Circuit Board, 0312-0163-01 Figure 13. Exploded view of RS-422 J-box Circuit Board Assy. On/Off Switch Labels Chassis Fuses (2), 5111-0017-21...
  • Page 10 Declarations This product can only be used with American Dynamics products and other approved products from Sensormatic Electronics Corporation. When the unit is hard wired, the disconnect device (circuit breaker) must be readily accessible. To meet regulatory approvals, only use approved polarized plug/cordsets.

This manual is also suitable for:

Rj856ud-1 series

Table of Contents