American Dynamics AD1416 Installation And Operating Instructions Manual
American Dynamics AD1416 Installation And Operating Instructions Manual

American Dynamics AD1416 Installation And Operating Instructions Manual

16-position sequential switchers

Advertisement

Quick Links

Models AD1416, AD1416L
16-Position
Sequential Switchers
Installation and Operating Instructions
This manual describes the installation and operating procedures for the American Dynamics model AD1416 and AD1416L
Sequential Switchers. The AD1416 and AD1416L are 16-position sequential video switchers with automatic alarm callup and
two video outputs. One video output provides the sequence of selected video inputs, interrupted during operator Holds and
system Alarms. The second video output provides the continuous sequence of inputs without interruptions, thus permitting
continuous viewing or recording of camera inputs.

Advertisement

Table of Contents
loading

Summary of Contents for American Dynamics AD1416

  • Page 1 Sequential Switchers Installation and Operating Instructions This manual describes the installation and operating procedures for the American Dynamics model AD1416 and AD1416L Sequential Switchers. The AD1416 and AD1416L are 16-position sequential video switchers with automatic alarm callup and two video outputs. One video output provides the sequence of selected video inputs, interrupted during operator Holds and system Alarms.
  • Page 2 The software/firmware furnished with this equipment is confidential to and is copyrighted by AMERICAN DYNAMICS. It is not to be copied or disclosed in any manner without the express written consent of AMERICAN DYNAMICS. This software is furnished to the purchaser under a license for use on a single system.
  • Page 3 I I I I N N N N S S S S T T T T A A A A L L L L L L L L A A A A T T T T I I I I O O O O N N N N A A A A N N N N D D D D S S S S E E E E R R R R V V V V I I I I C C C C E E E E If you require information during installation of this product or if service seems necessary, contact the American Dynamics Repair and Service Department at (800) 442-2225. You must obtain a Return Authorization Number and shipping instructions before returning any product for service.
  • Page 5: Table Of Contents

    Alarm Inputs ... 4 Auxiliary Inputs/Outputs ... 4 Power ... 4 OPERATION ... 5 Front Panel Controls ... 5 On-Screen Display... 5 TYPICAL SYSTEM CONNECTIONS AD1416... C-2 AD1416L ... C-3 Cascaded AD1416 Units... C-4 INDEX SPECIFICATIONS... Rear Cover CONTENTS Page...
  • Page 7: Product Description

    POWER DWELL MOVE PRODUCT DESCRIPTION The AD1416 and AD1416L are 16-position sequential video switchers with automatic alarm callup and two video outputs. One video output provides the sequence of selected video inputs, interrupted (blank) during operator Holds and system Alarms. The second video output provides the continuous sequence of inputs without interruptions, thus permitting continuous viewing or recording of camera inputs.
  • Page 8: Setup

    16 camera numbers, from 1 to 512. A six-position DIP switch (S22) located on the main PCB of the switcher is used to set the 16-camera block of on-screen camera numbers. As shipped, all units are set for camera block 1-16.
  • Page 9 Figure 2 - Location of Jumpers and DIP Switch on main PCB JUMPER DIP SWITCH CAMERA Figure 3 - AD1416 Rear Panel CAMERA Figure 4 - AD1416L Rear Panel 17 18 19 20 Figure 5 - J1 and J2 Pin Locations...
  • Page 10: Connections

    CONNECTIONS CONNECTIONS Video Inputs The AD1416 has 16 CAMERA input BNC connectors with 75-ohm terminations. The AD1416L model has 32 paired CAMERA BNC connectors, of which 16 are for video inputs and 16 are for passive looping outputs. If any video input is not looped through the AD1416L to other units, a 75-ohm BNC terminator must be connected to the matching connector.
  • Page 11: Operation

    Output A, pressing this pushbutton acknowledges (clears) the on-screen alarm. When all alarms have been acknowledged, the switcher returns to the previous state present prior to the alarms. While no alarms are present, the pushbutton is lit continuously when in the RUN mode and unlit when a camera is being held.
  • Page 13 Typical System Connections...
  • Page 14: Typical System Connections Ad1416

    TYPICAL SYSTEM CONNECTIONS AD1416 with 10 Cameras, Alarms, and VCR CAMERA 5 CAMERA 4 CAMERA 3 CAMERA 2 CAMERA 1 AD1461 MOTION DETECTORS CONTROL CONTROL CONTROL CONTROL CONTROL CAMERA MONITOR CAMERA 6 ALARM CONTACT 6 ALARM CONTACT 7 CAMERA 10...
  • Page 15: Ad1416L

    CAMERA 75-ohm Terminators Camera 8 Camera 1 MONITOR MONITOR TYPICAL SYSTEM CONNECTIONS AD1416L with 8 Cameras and Looping Outputs SWITCHER MONITOR CAMERA 5 CAMERA 6 CAMERA 7 CAMERA 8 10 11 12 14 15 16 17 18 19 20 120V...
  • Page 16 TYPICAL SYSTEM CONNECTIONS Cascaded AD1416's with 32 Cameras, 2 Monitors, and VCR CAMERA 16 Cameras 1 - 16 CAMERA 1 CAMERA 32 Cameras 17 - 32 CAMERA 17 CAMERA Cascading Video Connections CAMERA MONITOR MONITOR MONITOR Cascading Control Connection MONITOR...
  • Page 17: Index

    Index...
  • Page 18 TYPICAL SYSTEM CONNECTIONS AD1416 ........C-2 AD1416L .
  • Page 19 IF YOU ENCOUNTER ANY PROBLEMS OPERATING THIS UNIT, OR NEED ASSISTANCE, CALL OUR TECHNICAL SUPPORT CENTER: within the United States: 1-800-442-2225 outside the United States: (914) 624-7640...
  • Page 20: Specifications

    SPECIFICATIONS Supply Voltage: AD1416/AD1416L - 120VAC, 50/60 Hz AD1416X/AD1416LX - 230VAC, 50/60 Hz Power: 6 watts Mounting: Desktop or rack-mount Size: 1.88" H x 10.5" D x 16.2" W (48 x 267 x 411 mm) Weight: 4 lbs (1.8 kg)

This manual is also suitable for:

Ad1416l

Table of Contents