Ac Input; Wiring Ac Power Cables - Meyer Sound LYON-M Operating Instructions Manual

Linear line array loudspeaker
Table of Contents

Advertisement

LYON OPERATING INSTRUCTIONS
Loudspeaker
(230 V AC)
Line 1 (230 V AC)
Line 2 (230 V AC)
Line 3 (230 V AC)
Neutral
Earth/Ground
Figure 5: 230 V AC, 3-Phase Wye System (Single Line to Loudspeakers)
CAUTION:
For 230 V AC, 3-phase Wye
systems, never connect two lines to the AC
input of LYON, as the resulting voltage would exceed
the upper voltage limit (275 V AC) and will damage
the loudspeaker.

AC INPUT

The LYON user panel includes an AC Input connector that
supplies power to the loudspeaker. The 3-conductor
PowerCON 32 (Figure 6) is rated at 32 A and uses a locking
connector that prevents accidental disconnections.
Figure 6: PowerCON 32 AC Input Connector
LYON ships with a black powerCON 32 cable mount
connector, rated at 32 A, for assembling AC power cables.
Make sure to use an AC power cable that is wired correctly
(see "Wiring AC Power Cables" on page 12) and equipped
with the appropriate power plug (on the other end) for the area
in which you will operate the unit.
LYON requires a grounded outlet. To operate safely and
effectively, it is extremely important that the entire system be
properly grounded.
12
Loudspeaker
Loudspeaker
(230 V AC)
(230 V AC)

WIRING AC POWER CABLES

LYON ships with a black powerCON 32 cable mount
connector (Figure 7), rated at 32 A, for assembling AC power
cables. The pins on the powerCON 32 cable mount connector
are labeled as follows:
• L (Line)
• N (Neutral)
• PE (Protective Earth or Ground)
SIDE
Figure 7: PowerCON 32 Cable Mount Connector
How AC power cables are wired is determined by the type of
AC power distribution system used (see "AC Power
Distribution" on page 11). When wiring AC power cables for
single-line systems, use one of the wiring schemes described
in Table 1 and illustrated in Figure 8:
Table 1: AC Wiring Scheme
Wire Color
U.S. / Canada
60 Hz
Black
White
Green
Green and Yellow
Black (L)
White (N)
Green (E)
U.S./Canada, 60 Hz
Figure 8: AC Wiring Scheme, illustrated
CAUTION:
When wiring AC power cables and
distribution systems, it is important to preserve
AC line polarity and connect the earth ground on both
ends of the cable. LYON requires a grounded
connection. Always use a grounded outlet and plug.
It is extremely important that the system be properly
grounded to operate safely and properly. Do not
ground-lift the AC cable.
FRONT
REAR
L
N
Attach to the
Following
European
Terminal
50 Hz
Brown
Hot or live (L)
Blue
Neutral (N)
Protective earth /
ground (E or PE)
Brown (L)
Blue (N)
Green/
yellow (E)
Europe, 50 Hz
PE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lyon-wLyon-wxt

Table of Contents