Mub-Mina/Lina Load Ratings; Mub-Mina/Lina Angle Settings - Meyer Sound LEO Series Assembly Manual

Multipurpose grid
Table of Contents

Advertisement

MUB-MINA/LINA LOAD RATINGS

An array of up to five LINA loudspeakers can be flown with the MUB-MINA/LINA U-bracket at a 5:1 safety factor. When fly-
ing any number of LINAs with the U-bracket, the U-bracket must be secured to the mounting surface with either the two
1/2-inch center holes or the four 1/4-inch corner holes.
Table 11: MUB-MINA/LINA Load Ratings
Mounting Point
Safety
Factor
Two 0.5 in
5:1
center holes
Four 0.25 in
5:1
corner holes
Two 0.25 in
NA
center holes
When mounting the MUB-MINA/LINA on a pole, make sure the pole and pole-mount adapter have
CAUTION:
been rated to support the full weight of the U-bracket and loudspeakers. Observe all safety precautions speci-
fied by the pole and pole-mount adapter manufacturer.

MUB-MINA/LINA ANGLE SETTINGS

To allow for a range of angles for the attached LINA, one end of the MUB-MINA/LINA U-bracket has three fixed holes and
the other end has a single fixed hole and a slot. The U-bracket's holes and slots align with LINA's attachment points (two
per side). The screws and washers included with the MUB-MINA/LINA kit secure the U-bracket to the LINA cabinet.
Tables 12–15 on the following pages show the available angles for both flown and floor- and pole-mount configurations of
the MUB-MINA/LINA.
When using the MUB-MINA/LINA U-bracket for flown configurations, the U-bracket can be oriented for either maximum
downtilt (with the slot near the front of the loudspeakers) or maximum uptilt (with the slot near the rear of the loudspeak-
ers).
When using the MUB-MINA/LINA U-bracket for floor- and pole-mounted configurations, the U-bracket can be oriented
for either maximum downtilt (with the slot near the rear of the loudspeakers) or maximum uptilt (with the slot near the
front of the loudspeakers).
Number of Flown LINAs
Two LINAs (86.8 lbs, 39.2 kg) with
the load evenly distributed on the
two points
Five LINAs (217 lbs, 98 kg) with
the load evenly distributed on the
four points
Not rated for flown applications;
these holes should only be used
to attach the U-bracket to a pole-
mount adapter.
MG-MINA/LINA/750-LFC GRID ASSEMBLY GUIDE
MUB-MINA/LINA Mounting Points
Not rated for flown applications
59