Troubleshooting

This section covers what to do when:
• Dome does not respond to commands
• Fans do not turn
• Picture is grainy or discolored
• Poor video
• Ice forms on bubble.
CAUTION: Some steps in this section
involve tightening wire connections.
- Use a 2.5mm (0.1in) slotted
screwdriver. Using a blade too wide
can damage connectors.
- Screws on the ac connector are
delicate. DO NOT over tighten them!
Dome Does Not Respond to Commands
Follow steps until the problem is corrected. See
page 5 to order parts.
1. Detach the camera dome from the base and
check the address switches. Are they set
correctly?
- YES: Continue.
- NO: Set the correct address and reconnect
the dome.
2. Verify power is reaching the housing. Press and
hold switch SW2 on the environmental PC
board and observe the green (ac power) LED.
Does the LED glow steadily?
- YES: Reattach the dome and continue.
- NO: Check power at the J-box and ac cable
connections at connector P7 on the other
side of the environmental PC board. If OK,
replace the PC board.
Connector P7 pin outs
Pin
Color
1
N/A
2
N/A
3
N/A
SPEEDDOME ULTRA OUTDOOR HOUSING
INSTALLATION GUIDE - CONTINUATION
Description
24Vac
Common
24Vac
3. Verify data is reaching the housing.
SENSORNET or RS-422: Press and hold switch
SW2 on the environmental PC board and
observe the yellow (comm.) LED. The LED
should blink (SensorNet) or glow steadily
(RS-422).
To verify RS-422 connections at connector P1,
press and hold data test switch SW1 on
environmental PC board. Check the nearby red
and green LEDs; they indicate the following:
Constant green,
Blinking red
Constant green,
No red
Constant red,
Blinking green
Blinking red,
Green off
Both LEDs off
P1 pin outs:
Manchester data connections (Ultra IV only)
Pin
Color
1-4
5
White/Orange
6
White/Yellow
RS-422 Data connections
Pin
Color
1
Orange
2
Green
3
Yellow
4
Brown
5-6
9 of 12
RS-422 line is correctly
wired.
RS-422 "Data In –" is
shorted to ground.
"Data In + /–" wires are
reversed.
"Data In +" is shorted to
ground.
"Data In +/–" wires are
shorted or open.
Designation
Not used.
Manchester (White)
Manchester (Black)
Designation
RS-422 Data In High (+)
RS-422 Data In Low (–)
RS-422 Data Out High (+)
RS-422 Data Out Low (–)
Not used.
8200-0492-02, REV. B