AccuTemp XLR81B-00 Series Install, Service And Parts page 21

Upper heated platen
Table of Contents

Advertisement

3.6 DIE SPRING
1. Follow typical safety protocol for electrical and work space
and tools. Lock out tag out.
2. Disconnect from power source.
3. Remove the pivot assembly back cover.
4. Remove the pivot assembly bottom cover.
5. Measure the position of the 5/16" nylock nut that retains
the urethane die spring on the threaded shaft.
6. Use a ½" deep socket and remove the 5/16" nylock nut, 1
standard flat washer and 2 large flat washers and urethane
die spring from the threaded shaft.
7. To reinstall ensure a large flat washer is on either side of
the urethane die spring followed by the standard 5/16" flat
washer and 5/16" nylock nut. It is recommended that a
new 5/16" nylock nut is used to ensure proper locking of
the nut.
8. Tighten the nut until the depth measurement is the same
as taken in step 5.
9. Check for proper operation before installing the covers.
10. Reinstall the bottom cover and the back cover.
11. Apply power per the typical electrical safety protocol
MP5032-2104
XLR8 HEATED PLATEN
20