Timer does not activate
E
when Platen arm
depressed
F
Product undercooked
G
Product overcooked
MP5032-2104
1.
Manually depress 'Timer' button on control. If timer starts, refer to section
4.2.1 to reprogram to automatically start the timer.
2. Access the control panel interior and disconnect the magnetic proximity
switch from the board. Set up a multimeter to test for resistance across
the two wires leading to the proximity switch.
3. Test if the proximity switch closes when the arm is lowered. If the switch
does not close, replace the switch.
4. If the switch does close and the timer cannot be activated manually,
replace the control board.
1.
Adjust cooking time.
2. Adjust cooking temperature
3. Adjust platen height higher or lower.
XLR8 HEATED PLATEN