Installing The Software Utility; Riu Programming - American Dynamics AD100 Installation Instructions Manual

Ad100 series recorder controller & ir interface hookup / software
Hide thumbs Also See for AD100:
Table of Contents

Advertisement

Note: the cables wired at the recorder controller
should be arranged such that they do not cross in
front of, or block the IR receive sensor on the
recorder controller.
2.
Connect the modular cable and adaptors between
the AD100XA and the PC. The cable end with the
DB9M adaptor connects to the recorder controller.
The cable end with the DB9F adaptor connects to
the PC (see Drawing 3, page 5).
3.
Connect transformers to the power terminals of the
AD100XA and the power terminals of each
AD100IR16 to be used in the network. The two
transformer wires are non-polarized.
4.
Before connecting the modules' transformers to
nearby AC outlets, check all system connections.

Installing the Software Utility

1.
Install the RIU diskette into the PC's floppy drive.
2.
Click START and RUN.
3.
Type "A: \ setup.exe"
4.
Press the return (enter) key.
A blue screen appears, followed by four dialog boxes in
sequence:
1.
Welcome! (click NEXT).
2.
Ready to Install (click NEXT).
3.
Select Destination Directory (accept or change the
defaults, then click NEXT).
4.
Installation Completed! (click FINISH).
The software is installed. If the defaults are accepted,
the following is true:
1.
A group is added to the start menu with the path
"American
Dynamics\Recorder
Utility."
2.
A new folder is created with the path "C:\Program
Files\American Dynamics\AD100RIU".
3.
An executable file called "riu.exe" resides in the
RIU folder.
4.
A new folder called "Recorder Library" resides in
the C drive.
5.
Four VCR files are installed in the "Recorder
Library" folder. The filenames refer to four
standard VCRs denoted by brand name and model
number.
Launching the Application
On the Windows desktop, click the following sequence:
1.
"Start"
2.
"Programs"
3.
"American Dynamics"
4.
"Recorder Installation Utility"
4
Recorder Controller/Interface Installation Instructions
The initial window of the RIU software appears:

RIU Programming

The user can now perform the following actions:
Set the addresses for the IR Interface Modules
Map the recorder types to be used in the system
(this typically specifies the make and model of the
recorder). The user will either select recorder types
available as pre-programmed default models, or
will specify different recorder types and "learn" the
IR command set for each non-default model.
Select module types, and assign recorder types and
recorder numbers to each output of the selected
modules.
Save the map file and transfer it from the PC to the
AD100XA.
Auto Addressing Modules
Auto addressing sets the addresses on all of the
Installation
100IR16 modules connected in the daisy chain.
1.
Select Functions/Controller Setup/Auto Address
Modules. A dialog box appears.
2.
Wait 30 seconds. Press the push-button addressing
switch on the right hand side of the first 100IR16
module (press the switch with a non-conductive
implement such as the eraser end of a number 2
lead pencil). The dialog box message will change to
"Looking for Module 2". Press the addressing
switch on the second 100IR16 module. Continue
the procedure until all N 100IR16 modules have
been addressed.