Carrier BWCAAG000120 Installation & Operating Instructions Manual page 29

Contractors
Hide thumbs Also See for BWCAAG000120:
Table of Contents

Advertisement

Crawl Space and Attic combustion air
Alberta and Saskatchewan Vent Terminations
The Provinces of Alberta and Saskatchewan require a
minimum unobstructed distance of 4ft. (1.2m) from the foundation
to the property line of the adjacent lot for vent termination of
any appliance with an input over 35,000 btuh. If there is less
than 4 ft. (1.2m) of unobstructed distance to the property line
of the adjacent lot, no type of vent termination is permitted for
appliances with inputs greater than 35,000 btuh.
There are no additional restrictions on unobstructed distances
greater than 8ft. (2.4m). All single, two-pipe and concentric
vents may be used, providing all other Code and manufacturer's
requirements in these instructions are adhered to. Refer to the
appropriate Vent Termination section above for locating the vent
termination.
If the unobstructed distance from the foundation to the property
line of the adjacent lot is no less than 4ft. (1.2m) and no greater
than 8ft. (2.4m), it will be necessary to re-direct the flue gas
plume. In this situation, a concentric vent kit cannot be used.
A 2-pipe termination (or single pipe termination when permitted
with ventilated combustion air applications) that re-directs the
flue gas away by use of an elbow or tee, certified to ULC S636
from the adjacent property line must be used. See fig. beside.
The kit currently cannot be modified to attach an elbow to the
vent portion of the rain cap. A tee attached to the rain cap could
potentially direct the flue gas plume toward the intake air stream
and contaminate the incoming combustion air for the boilers.
Refer to figure below for terminations approved for use in Alberta
and Saskatchewan.
Ventilated combustion
air intake pipe
Pipe hangar
3" (76 mm)
Ventilated combustion
air intake termination in
crawl space
CRAWL SPACE
Vent through roof flashing
ATTIC
12" (305 mm)
Ventilated combustion
air intake pipe
12" (305 mm) min above
highest level of insulation
OPTIONAL TERMINATION
BRACKET FOR 2-PIPE
TERMINATIONS
12 IN. (305 mm) MIN.
SEPARATION BETWEEN
BOTTOM OF COMBUSTION
AIR AND BOTTOM OF VENT.
12 IN. (305 mm)
ABOVE ANTICIPATED
SNOW LEVEL
EXHAUST
CLEARANCE TO OVERHANG PER
CODE
29
CRAWL SPACE
For vent and combustion air pipe
length refer to the approved configu-
ration of horizontal and vertical vent
installation - Section 8.8, fig. 7 for 2"
and fig. 20 for 3"
9
WARNING: When using
a ventilated crawl space
for combustion air ensure
the make-up air opening
is adequately sized for
the boiler per National
Flue Gas Code, ANSI
Z223.1/NFPA 54as well
as applicable provisions
of the local building code,
in
the
United
and
CAN/CGA B149.1,
Installation Codes as well
as applicable provisions of
the local building code, in
Canada.
ATTIC
For vent and combustion air pipe
length refer to the approved con-
figuration of horizontal and ver-
tical vent installation - Section
8.8, fig. 13-14 for 2" and fig. 18-
19 for 3"
9
WARNING:
a ventilated attic space
for combustion air ensure
the make-up air opening
is
adequately
the
boiler
Flue
Gas
Z223.1/NFPA 54as well as
applicable provisions of the
local building code, in the
United States and CAN/
CGA B149.1, Installation
Codes as well as applicable
provisions
building code, in Canada.
OVERHANG OR ROOF
VENT
Angle 22.5°
to 45° off wall
OPTION
12 IN. (305 mm) MIN.
BRACKET
12 IN. (305 mm) MIN.
SEPARATION
COUPLING
SEPARATION
BETWEEN BOTTOM OF
BETWEEN BOTTOM OF
COMBUSTION AIR AND
COMBUSTION AIR AND
BOTTOM OF VENT.
MAINTAIN 12 IN. (305 mm)
CLEARANCE ABOVE
HIGHEST ANTICIPATED
SNOW LEVEL OR GRADE,
COMBUSTION-AIR
WHICHEVER IS GREATER.
(ELBOW PARALLEL TO WALL)
OVERHANG
12 IN. (305 mm) MIN. GROUND
LEVEL OR ANTICIPATED
SNOW LEVEL
States
When
using
sized
for
per
National
Code,
ANSI
of
the
local

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bwcaag000150Bwhaag000120Bwhaag000150