DESCRIPTION

The 2033 Auxiliary Follower provides relay closures which
correspond to an auxiliary call for a selected or switched
camera. The auxiliary function(s) (either 1, 2, or 3) can be
activated eithere manually from a keyboard, from a system
tour, or from an alarm. The Auxiliary Follower can address
one to 1024 cameras in groups of 16.
The 2033 is typically used where a high concentration of
auxiliary devices (i.e., electronic door switches or auxiliary
lighting) need to be controlled, but where pan/tilt functions
are not necessary. Note: The use of the 2033 does not negate
the use of the pan/tilt control at a remote site.
Additionally, the 2033 can provide contact closures
coordinated with an alarm callup. The contact closure occurs
when the corresponding camera is automatically placed into
alarm from an external device.
The 2033 receives data from either a LAN output of a 1995, a
DATA LINE output of a 1996, or a Control Code output of a
Matrix Switching System. If the 2033 operates via control
code, a dip switch located on the 2033's main printed circuit
board, is used to select the Control Code mode.
5
6
A B
A B
A B
A B
A B
21
3
18
A B
A B
A B
A B
A B
4
23
Figure 1 - 2033 Auxiliary Follower
9
A B
A B
A B
10
A B
A B
25
7
11
22
A B
A B
A B
A B
A B
8
24
28
The 2033 filters the incoming codes for auxiliary commands
and camera group. The unit contains 32 addressable,
normally open relays. The 32 relays can be grouped in series
or in two alike groups of 16. Each of the two groups can
control 16 relays.

FEATURES

The 2033 Alarm Responder has the following features:
SCREW TERMINAL WIRE CONNECTORS
LED INDICATOR FOR "VALID" CODE
LED POWER INDICATOR
DIP SWITCH SELECTION FOR CAMERA GROUP
AND AUXILIARY
COMPATIBLE WITH EITHER DATA LINE OR
CONTROL CODE
UNIVERSAL MOUNT CABINET
1
DESCRIPTION
13
14
A B
A B
A B
A B
A B
29
15
26
30
16
A B
A B
A B
A B
A B
12
31
G1 IN G1 OUT G2 IN G2 OUT
27
32
A B
A B
A B
A B
DATA LINE
IN
OUT
120V
60HZ

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ad2033-12033

Table of Contents