Leak testing
WARNING
Risk of explosion! Never use a naked fl ame to check for leaks.
Never leak test while smoking.
The gas connections on this appliance are leak tested at the factory prior to
shipment. This appliance needs to be periodically checked for leaks and an
immediate check is required if the smell of gas is detected.
Make a soap solution using
1 part of liquid dish-washing
soap to 3 parts water. The
soap solution can be applied
with a soap bottle, brush, or
rag to the leak tested points
shown in the fi gure (right).
The valve of the gas cylinder
should be in the OFF
position at this point of the
leak test. Once the soapy
solution is applied to the gas
connections, the valve of
the gas cylinder needs to be
turned to the ON position.
Soap bubbles will begin to
form in the soapy solution if a
leak is present.
In case of a leak, turn off
the gas supply. Tighten any
leaking fi ttings, then turn the
gas supply on and recheck.

OPERATION

Important instructions on operation
The glass window is a hot part, don't touch it while it is working!
In case of glass breakage, shut off all burners and any heating element.
Do not touch the appliance surface.
Do not use the appliance before leakage test.