Bosch rexroth MSK Series Operating Instructions Manual page 44

Synchronous servomotors
Hide thumbs Also See for rexroth MSK Series:
Table of Contents

Advertisement

30/57
Assembly
Terminal box type RKL1200, RKL1300
6
1
2
Power cable connection at the ter‐
minal box
Bosch Rexroth AG R911325169_Edition 03
3
3
5
4
①⑤
Screw connection
O-ring
Adapter plate to accommodate the screw connection
Reduction (optional for cable cross-sections 1.5, 2.5 mm²)
Adapter plate mounting screws
Cover screws
Cover
Seal of terminal box cover
Fig. 6-9:
Assembly RKL1200, RKL1300
The power connection is made in single or double wiring. The assembled
power cables are inserted into the terminal box via the adapter plates (2 ×
M40×1.5) and cable glands.
Connecting the power cable to the terminal box requires the following steps:
1.
Open the terminal box cover.
Loosen and remove the mounting screws (4 pieces).
2.
Remove the protective cover of the cable gland.
3.
Detach the adapter plate ③ from the terminal box.
4.
Screw the adapter plate firmly to the metric cable gland on the power
cable. Use reduction for power core cross-sections of 1.5 mm² and
2.5 mm².
Before attaching the power cable to the adapter plate, check the correct
condition and position of the O-ring.
5.
Feed the power cable up to the adapter plate through the opening in the
terminal box and fasten the adapter plate to the terminal box.
Tightening torque of the screws ⑥: 9 Nm (±10%)
8
7
9
2
3
MSK Synchronous Servomotors

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents