BO800RN
Retrofi t housing and retrofi t handles

Product Details

Description
Number of 400Kg
magnets
Lock section
with cover
Architectural handle
with fi xing cover
End caps for handle
End caps
for lock section
RAL colour (option)
Finishes
Description
Number of 400Kg
magnets
Lock sction
with cover
Architectural handle
with fi xing cover
End caps for
handle
End caps for
lock section
RAL colour
(option)
Cut-to-length service
provided (optional)
Magnets & armatures supplied
non-mounted (specify)
2] INFORMATION & RECOMMANDATIONS
2] INFORMATION & RECOMMANDATIONS
Information
The electromagnets are pre-fi tted within the lock
section. The armature plates are pre-fi tted within
the architectural handle. Both sections are supplied
with end caps.
Power Considerations
The handle is designed to house electromagnets
with a holding force of 400Kg each. These units
can be supplied by either 12Vdc or 24Vdc depending
upon your preferred choice. The current required
depends on the amount of electromagnetic locks,
and the voltage chosen – please see Technical
Specifi cation, and ensure you have allocated
suffi cient power to correct performance. For example,
the BO800RN2.5m (2.5m housing with 2 magnetic
locks) would require:
- PSU12/2 or ARD2/12 at 12Vdc
BO800RN
BO1200RN
2,5 m
2,5 m
Bandeau
Bandeau
(2500 mm)
(2500 mm)
2
3
1
1
1
1
2
2
2
2
Standard
(Ref. Product) (Ref. Product)
AL
Anodised
aluminium (SAA)
-
BO800RN
BO1200RN
3 m
3m
Bandeau
Bandeau
(3000 mm)
(3000 mm)
2
3
1
1
1
1
2
2
2
2
(Ref. Product) (Ref. Product) (Ref. Product)
CH
BL
Anodised
RAL Black
champagne
-
-
-
-
PSU24/1 or ARD24 at 24Vdc.
General Advice
The 2 parts of the architectural housing are designed
to be surface mounted on the door and frame,
where they should be parallel when the door is closed.
If there is a rebate, then it will be necessary to pack
out the lower part to be parallel to the other.
(Option of kit to provide 2, 4 or 10 mm packing).
Wiring
Plan your cable routes before commencing installation.
We recommend a maximum distance of 10m
from the power supply to the electromagnetic locks
(to prevent volt drop). If the distance is greater,
then make sure you have increased the cross section
of the cable to compensate.
PBO800RN
PBO400RN
60 cm
40 cm
Bandeau
Bandeau
(600 mm)
(400 mm)
2
1
1
1
1
1
2
2
2
2
WH
RAL White
Untreated
-
www.cdvi.com
www.cdvigroup.com
Housing
-
-
-
-
BT
-
-
3