Location

This appliance should be installed in a
dry, well-ventilated room.
When deciding where to install your re-
frigeration appliance please bear in
mind that it will use more energy if in-
stalled near to a heater, a cooker or
other appliance that gives off heat. Dir-
ect sunlight should also be avoided.
The higher the room temperature, the
longer the compressor runs and the
higher the energy consumption is.
When installing the appliance, please
note:
- The socket must be easily accessible
in an emergency, not concealed be-
hind the appliance.
- The plug and cable must not touch
the rear of the appliance as they
could be damaged by vibrations from
the appliance.
- Do not plug in other appliances be-
hind this appliance.
Risk of damage due to high hu-
midity.
In environments with high humidity,
condensation can build up on ex-
ternal refrigeration appliance panels,
which can cause corrosion.
Install the refrigeration appliance in a
dry and/or air-conditioned room with
sufficient ventilation.
After installation, make sure that the
appliance door closes properly, the
ventilation gaps are not covered and
that the refrigeration appliance has
been installed in accordance with the
operating and installation instruc-
tions.
Climate range
The appliance is designed for use within
a certain climate range (ambient tem-
peratures) and should not be used out-
side this range. The climate range of the
appliance is stated on the data plate in-
side the appliance.
Climate range
SN
N
ST
T
Operating in a room which is too cold
will cause the compressor to switch off
for too long, causing the internal tem-
perature in the appliance to rise with the
risk of food deteriorating and going off.

Ventilation

Risk of fire and damage due to
insufficient ventilation.
If the refrigeration appliance is not
ventilated sufficiently, the com-
pressor will run more frequently and
for longer periods. This will result in
increased energy consumption and a
higher operating temperature for the
compressor. This may, in turn, cause
damage to the compressor.
Please ensure that there is adequate
ventilation around the refrigeration
appliance.
It is essential to observe the required
ventilation gaps. The ventilation gaps
must not be covered or blocked in
any way.
Installation
Ambient room
temperature
+10 to +32 °C
+16 to +32 °C
+16 to +38 °C
+16 to +43 °C
47