Download Print this page

Honeywell Resideo ADEMCO 4101SN V-Plex Installation And Setup Manual page 2

Single output relay module

Advertisement

Specifications
Physical: Width: 2-1/8" (53mm)
Height: 3-1/4" (84mm) Depth: 1" (25mm)
Electrical:
Polling loop input voltage range: 8-12VDC
Polling loop current draw: 7mA (continuous)
Relay contact rating: 2A @ 28VAC/VDC, resistive loads
Aux Zone:
10k EOLR (internal when white jumper intact; external
when white jumper cut
300 ohm max zone resistance (excluding EOLR)
Responds to open or short circuit faults having 250mSec
or longer duration
Class B (style B when used with panels providing earth
ground fault detection)
For UL Commercial Fire Applications, must be used as
N.O. zone and white jumper must be cut
TERM. ASSIGNMENT
1 (+) POLLING LOOP
2
( )
POLLING LOOP
3 (+) AUX ZONE (+)
4
RELAY N.O.
5
RELAY N.C.
6
RELAY C
POLLING LOOP
TERMINALS ON
CONTROL
+
+
POLLING LOOP - CLASS B, STYLE 4
MAX WIRING IMPEDANCE 25 OHMS
Always Observe Polarity.
Always Connect In Parallel.
See Panel's I.I. Text For Wire Gauge
And Wire Length Requirements.
V-Plex and Aux Circuits are supervised
and power-limited.
Figure 1. 4101SN V-Plex Single Output Relay Module
SEE THE CONTROL PANEL'S INSTALLATION INSTRUCTIONS FOR COMPLETE INFORMATION
REGARDING LIMITATIONS OF THE ENTIRE SECURITY SYSTEM.
ÊK3166V3B>Š
K3166V3B 10/12 Rev. B
Agency Listings
UL864 Commercial Fire
UL985 Household Fire
UL1023 Household Burglary
UL609 Commercial Burglary
CSFM
FM
MEA
Warranty
For the latest warranty information, please go to:
http://www.honeywell.com/security/hsc/resources/wa/
MOUNTING
(+)
4101SN
CASE BACK
( )
TERMINAL
BLOCK TB1
(SUITABLE FOR
14-22 AWG WIRE)
N.O. N.C.C
OTHER
TM
V-PLEX MODULES
1 2 3
+
AUX.
ZONE
N.O.
10K EOLR
(USE ONLY IF WHITE
JUMPER IS CUT)
Corporate Center Drive, Suite 100
2
P.O. Box 9040, Melville, NY 11747
© 2020 Resideo Technologies, Inc.
www.resideo.com
MOUNTING SCREW
HOLES (IN CASE BACK)
COVER SCREW HOLE
WHITE JUMPER
TAMPER SWITCH
4 5 6
WIRING ACCESS
HOLES (SLOTS)
RELAY C CONTACT
RELAY N.C. CONTACT
RELAY N.O. CONTACT
MOUNTING SCREW HOLE
(IN CASE BACK)
N.C.
If switching power through a
relay, the power must be from
a power-limited source.
Relays are programmable but
outputs are not supervised.
4101SN-001-V5

Advertisement

loading