Loosen the battery compartment screw a 1/4 turn, then tighten the
battery compartment screw.
Apply gentle pressure to the battery compartment as you tighten it.
If the battery compartment screw is not tight, the base of the battery
compartment may not make a good connection with the spider, and
cause an intermittent signal.
4
Lift the battery contact prongs upward.
If the battery contacts are flattened, the battery may move around the
compartment, and cause an intermittent signal.
5
Check for proper battery height. Install a new CR2032 coin cell battery
into the battery compartment, positive side facing outward. When the
battery contact prongs are properly adjusted, the top of the battery will
protrude above the lip of the battery compartment.
Consult the battery manufacturer for safe handling instructions. Keep
the battery out of reach of children. Do not put the battery in your
mouth. If ingested, seek medical attention immediately. Do not use
sharp objects to remove batteries.