MSK-101-POE
Intelligent motion sensor
Power over Ethernet
Advanced configuration manual
v1.1 - EN
Carefully read this manual in its entirety.
You will find useful information to take full advantage of the product's potential, use it safely and obtain the best results.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Tsec MSK-101-POE and is the answer not in the manual?

Questions and answers

Summary of Contents for Inxpect Tsec MSK-101-POE

  • Page 1 MSK-101-POE Intelligent motion sensor Power over Ethernet Advanced configuration manual v1.1 - EN Carefully read this manual in its entirety. You will find useful information to take full advantage of the product's potential, use it safely and obtain the best results.
  • Page 2 Transferring the document on websites or other electronic systems. Copying contents without any modification and stating Inxpect SpA as copyright owner. Inxpect SpA reserves the right to make modifications or improvements to the relative documentation without prior notice. Requests for authorization, additional copies of this manual or technical...
  • Page 3 5.1 Technical data 5.2 Examples of main direction 5.3 Disposal 5.4 Conformity and restrictions 5.5 Service and warranty 5.6 Useful conventions for requesting assistance 5.7 Back plate dimensions MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 4 PDF online Intended users of this manual Designers, systems integrator and installers of anti-theft systems, previously trained by Inxpect. Only this training and the information provided in this manual ensures the designing and installing of effective anti-theft systems. MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 5 Sensor case Adjustable support for the sensor with integrated fastening screws Sensor Ferrule Cable protection ring H Cable protector Caps to cover the fastening screws of the adjustable support MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 6 1.2.3 API documentation For detailed information about the implemented APIs and to integrate them into your system, refer MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 7 (vertical direction). 2.1.2 Examples of volumetric sensor installation Indoor ceiling installation. Indoor wall installation. MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 8 2.  Useful information for design Indoor ceiling installation. Outdoor installation. 2.1.3 Examples of barrier sensor installation Indoor wall installation. Indoor hallway installation. MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 9 70° along the horizontal plane and 30° on the vertical plane. It extends for a maximum of 20 m, following the radiation pattern of the antenna. Example of installation with bracket. Top view. MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 10 ). For details about discerning animals, see "Set the tolerance level for animals" on page 22. Note *: discernment of animals is not guaranteed in the entire field of vision. MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 11 Unusually intense rain (heavy storms with intensities exceeding 20 mm/h (0.80 in/h)) can reduce the field of vision by up to 50%. Hail may cause false alarms. MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 12 Note *: see "Examples of the field of vision with horizontal sensor direction (volumetric)" on page 10 and "Examples of the field of vision with vertical sensor direction (barrier)" on the previous page. Front-front combination MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 13 Up to three channels are available (channel A, B, C). An example of an installation with nine sensors and relative channel assignments is presented as follows. MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 14 6. Only for installations with MSK-101-BM bracket, define the direction of the sensor (see "Barrier configuration" on page 9). MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 15 4. Insert the cable protector in the cable. If the cable already has a terminal, see "Procedure with cable already with terminal" on the next page. 5. Terminate the cable using an RJ45 connector. MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 16 RJ45 connector into the Ethernet port, see steps 2–9 of the "Assemble the sensor" on the previous page procedure. MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 17 7. Insert the ferrule, the cable protection ring and the cable protector in the cable and insert the RJ45 connector into the Ethernet port, see steps 2–9 of the "Assemble the sensor" on page 15 procedure. MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 18 Step 3: Calibration page, perform the calibration procedure (see "Calibrate the sensor" on page 20). 9. On the Step 4: Configuration page, set the alarm area and possible pre-alarm area. MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 19 See "Calibrate the sensor" on the next page. Channel 1. "Access to the web interface" after on the previous page. adding 2. On the main menu select Sensor settings. sensors to the area MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 20 Calibration must be performed during the first configuration of the For more information, see "Field of vision" on sensor or at each new installation. page 9. MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 21 3. On the main menu, select Configuration and check that a motion generates an alarm in the entire monitored area (see "Check the calibration" below). MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 22 The tolerance for animals can be set to a value from 0 to 100. The maximum tolerance level is the recommended level to minimize outdoor false alarms. MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 23 Semi-static objects can be configured as follows: masking signal level" on page 20 set the tampering signal level, see "Set the tampering signal level" on page 20 and type of MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 24 On the main menu > Sensor settings it is possible set the measurement system (Imperial or Metric) set the language update the firmware change the access password restore factory default settings MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 25 "Problem with the security certificate. where the access occurred and is valid for all MSK-101-POE certificate") sensors. Note: if the problem persists, contact technical assistance, see "Service and warranty" on page 29. MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 26 Remove any dust or dirt from the outside of the sensor and case using a slightly damp cloth. Do not use abrasives or solvents. Check correct functioning after cleaning. MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 27: Table Of Contents

    Note**: the instructions presented in this manual are sufficient for meeting the requirements of standard UL639. Installations not consistent with these instructions could also comply with the standard. MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 28: Examples Of Main Direction

    NOTICE: changes or modifications made to this equipment and not explicitly approved by Inxpect SpA may void the FCC authorization to operate this equipment. MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 29: Service And Warranty

    5.5.3 Warranty To find out about the terms of the warranty, exclusions and cancellation of the warranty, refer to the website www.tsec.it. MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 30: Useful Conventions For Requesting Assistance

    5.6.1 Conventions Some useful conventions to communicate with Inxpect SpA technical assistance are provided below. 5.6.2 Type of application 5.6.3 Spatial direction Legend Icon Description Wall installation Ceiling installation MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 31: Back Plate Dimensions

    5.  Appendix 5.7 Back plate dimensions MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA...
  • Page 32 Via Luigi Becchetti, 74 25081 Bedizzole (BS) Italy www.tsec.it info@tsec.it +39 030 57 85 302 Inxpect SpA Via Serpente, 91 MSK-101-POE 25131 Brescia (BS) Advanced configuration manual v1.1 Italy DEC 2019 www.inxpect.com msk-101-poe_advanced-config_en_wo v1.1 security@inxpect.com Copyright © 2019 Inxpect SpA +39 030 5785105...