Inxpect MSK-101 Advanced Configuration Manual

Intelligent motion sensor

Advertisement

Quick Links

MSK-101
Intelligent motion sensor
Advanced configuration manual
v1.5 - EN
Carefully read this manual in its entirety.
You will find useful information to take full advantage of the product's potential, use it safely and
obtain the best results.
Exclusive distributor for Europe

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MSK-101 and is the answer not in the manual?

Questions and answers

Summary of Contents for Inxpect MSK-101

  • Page 1 MSK-101 Intelligent motion sensor Advanced configuration manual v1.5 - EN Carefully read this manual in its entirety. You will find useful information to take full advantage of the product's potential, use it safely and obtain the best results. Exclusive distributor for Europe...
  • Page 2 All rights reserved in all countries. Any distribution, alteration, translation or reproduction, partial or total, of this document is strictly prohibited unless with prior authorization in writing from Inxpect SpA, with the exception of the following actions: Printing the document in its original format, totally or partially.
  • Page 3: Table Of Contents

    Other operations Maintenance and diagnostics Diagnostics and troubleshooting Updates Maintenance Appendix Technical data Disposal Conformity and restrictions Service and warranty Useful conventions for requesting assistance Perforated base dimensions MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 4 2018 Intended users of this instruction manual Designers or installers of anti-theft systems, previously trained by Inxpect. Only this training and the information provided in this manual ensures the designing and installing of effective anti-theft systems. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 5: Get To Know Msk-101

    Get to know MSK-101 Contents This section includes the following topics: MSK-101 Relay outputs MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 6: Msk-101

    Note: during the initialization phase, the integral part of the sensor anti-removal masking signal is disabled. and anti-tear system. Sensor housing Adjustable support for the sensor with integrated fastening screws Sensor MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 7: Relay Outputs

    (Inxpect Security > > General). The status of the relays is indicated in the homepage of the application to facilitate on-site inspections during the installation phase. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 8: Useful Information For Design

    Useful information for design Contents This section includes the following topics: Applications Barrier configuration Field of vision Interferences MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 9: Applications

    (vertical direction). Examples of volumetric sensor installation Figure 2 - Indoor ceiling installation. Figure 1 - Indoor wall installation. Figure 3 - Outdoor installation. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 10 Examples of barrier sensor installation Figure 4 - Indoor wall installation. Figure 6 - Indoor hallway installation. Figure 5 - Indoor ceiling installation. Figure 7 - Outdoor installation with adapter. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 11: Barrier Configuration

    Figure 14 - Top view. Figure 10 - Sensor directed towards the left. Figure 15 - Side view. Figure 11 - Sensor directed towards the right. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 12 If a pre-alarm area 1.5 4.9 0° is not defined, the alarm area corresponds to the 2 6.5 -15° entire monitored area. 2 6.5 -30° 2.5 8.2 -15° 2.5 8.2 -30° MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 13: Interferences

    50%. Hail may cause false alarms. If exposed to precipitation, install the sensor parallel to the usual direction of the precipitation. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 14 - Front-front combination Figure 17 - Front-back combination Figure 18 - Back-back combination Note: the blind spot created in this combination is very wide. If possible, use the back-front configuration. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 15: Installation And Use

    Installation and use Contents This section includes the following topics: Installation and configuration Use the application Set the tolerance level for animals Manage semi-static objects Other operations MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 16: Installation And Configuration

    Warnings NOTICE: damage to the device. Do not let dust 2. Extract the sensor from the adjustable support. or water near the sensor during installation. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 17 (not provided). See "Perforated base dimensions" on page 32. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 18 2. Assemble the adapter to the base, passing the cable with the wires coming out of the alarm control unit into the adapter. 6. Extract the sensor from the adjustable support. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 19 Connect the sensor to the alarm control unit 1. Remove the sheath and the hose by at least 5 cm (2 in). 2. Turn the sensor to lock it into the adjustable support. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 20 (see the dongle instruction sheet for the default password). 5. If other sensors are present in the area, assign a specific channel to the sensor, or select "None". MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 21 Fasten the sensor 1. Tighten the screws to fasten the adjustable support. Check in the application that the adjustable support has not moved. 5. Insert the provided caps. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 22: Use The Application

    Set the masking signal level 3. Select > General. homepage > > General The tampering signal level can be: aggressive, standard, disabled. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 23: Set The Tolerance Level For Animals

    If necessary, set two semi-static objects: one for the object and one for its projection on the wall. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 24: Other Operations

    2. Move near the semi-static object or move the semi-static object. 3. Check that the detected moving object appears on the screen, and that the alarm/pre-alarm LED stays off. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 25: Maintenance And Diagnostics

    Maintenance and diagnostics Contents This section includes the following topics: Diagnostics and troubleshooting Updates Maintenance MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 26: Diagnostics And Troubleshooting

    At each start-up the application will check for and download any possible update for the application, dongle and sensor. The updates are saved locally for subsequent installation. Download updates and display saved updates Select the button on the application homepage. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 27: Maintenance

    Remove any dust or dirt from the outside of the sensor and housing using a slightly damp cloth. Do not use abrasives or solvents. Check correct functioning after cleaning. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 28: Appendix

    Appendix Contents This section includes the following topics: Technical data Disposal Conformity and restrictions Service and warranty Useful conventions for requesting assistance Perforated base dimensions MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 29: Technical Data

    NOTICE: changes or modifications made to this equipment and not explicitly approved by Inxpect SpA may void the FCC authorization to operate this equipment. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 30: Service And Warranty

    F. +39 012 3456789 supporto@tsec.it www.tsec.it Service and warranty To find out about the terms of the warranty, exclusions and cancellation of the warranty, refer to the website www.tsec.it. MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 31: Useful Conventions For Requesting Assistance

    Conventions Some useful conventions to communicate with Inxpect SpA technical assistance are provided below. Type of application Spatial direction Legend Icon Description Wall installation Ceiling installation MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 32: Perforated Base Dimensions

    Appendix Perforated base dimensions MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA...
  • Page 34 25081 Bedizzole (BS) Italy www.tsec.it info@tsec.it +39 030 57 85 302 Manufacturer: Inxpect SpA Via del Serpente, 89 MSK-101 25131 Brescia (BS) Advanced configuration manual v1.5 Italy MAY 2018 www.inxpect.com msk-101_advanced-config_en_wo v1.5 security@inxpect.com Copyright © 2017-2018 Inxpect SpA +39 030 254 0300...

Table of Contents