Inxpect MAGNASPHERE MOTION MSK-101-MM Installation Instructions Manual

Intelligent motion sensor

Advertisement

MSK-101-MM
Intelligent motion sensor
Installation instructions
v1.7 - EN
Carefully read this manual in its entirety.
You will find useful information to take full advantage of the product's potential, use it safely and obtain the best results.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MAGNASPHERE MOTION MSK-101-MM and is the answer not in the manual?

Questions and answers

Summary of Contents for Inxpect MAGNASPHERE MOTION MSK-101-MM

  • Page 1 MSK-101-MM Intelligent motion sensor Installation instructions v1.7 - EN Carefully read this manual in its entirety. You will find useful information to take full advantage of the product's potential, use it safely and obtain the best results.
  • Page 2 Transferring the document on websites or other electronic systems. Copying contents without any modification and stating Inxpect SpA as copyright owner. Inxpect SpA reserves the right to make modifications or improvements to the relative documentation without prior notice. Requests for authorization, additional copies of this manual or technical...
  • Page 3: Table Of Contents

    Installation and use Before installation Install and configure the sensor Appendix Technical data Disposal Conformity and restrictions Service and warranty Download Useful conventions for requesting assistance Perforated base dimensions MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 4 First publication v1.0 Provided documentation Distribution Document Code Date format PDF online Installation instructions (this msk-101-mm_instructions_en_us v1.7 manual) 2018 Advanced configuration manual msk-101-mm_advanced-config_en_us online manual v1.7 2018 PDF online MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 5: Get To Know Msk-101-Mm

    (vertical direction). MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 6 Get to know MSK-101-MM Examples of volumetric sensor installation Outdoor installation. Indoor wall installation. Examples of barrier sensor installation Indoor ceiling installation. Indoor wall installation. MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 7: Barrier Configuration

    15 cm (5.9 in) from the same wall. If other adequate supports are not available, an adapter is necessary for assembling the barrier (product code: MSK-101-BM. Example of installation without adapter. Indoor hallway installation. MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 8: Field Of Vision

    Based on a specific installation height, there are direction and inclination combinations that guarantee optimum performance. Some examples to better explain the effects of height and inclination are presented as follows. MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 9: Interferences

    The dimensions of the field of vision expressed in "Examples of the field of vision with vertical sensor meters and feet are as follows. direction (barrier)" above. h (m) α (°) MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 10 Front-front combination Front-back combination Back-back combination Note: the blind spot created in this combination is very wide. If possible, use the back-front configuration. MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 11: Installation And Use

    (see "Barrier configuration" on page 7). Warnings NOTICE: damage to the device. Do not let dust or water near the sensor during installation. MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 12: Install And Configure The Sensor

    3. Pass the cable with the wires coming out of control unit into the adapter. the alarm control unit into the sensor housing. MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 13 5. Assemble the sensor housing to the adapter. 3. Unscrew the fastening screws on the pre- assembled base of the adapter. MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 14 It is recommended to connect relay 3 (tampering) and 4 (fault) to a 24 h line from the alarm control unit. 7. Pass the cable into the sensor housing. MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 15 1. Insert the dongle into its caddy. 2. Turn the sensor to lock it into the adjustable support. 3. Turn the adjustable support to orient the sensor direction vertically (barrier application) or horizontally (volumetric application). MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 16 3. Turn the sensor to bring it back to the horizontal/vertical position. 45° downward inclination To make the connector for connecting the dongle accessible, turn the adjustable support by 180°. MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 17 Installation and use 4. Fasten the body of the sensor to the base using the provided screw. 5. Insert the provided caps. MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 18: Appendix

    Cable 4–7 mm (0.16–0.27 in) environment and population. diameter Approvals Contains FCC ID: UXS-SMR-3X4 Compatible with EN50131-2-3 class IV grade 3** MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 19: Conformity And Restrictions

    24-24,25 GHz. Définissez le pays correctement dans l’application Inxpect Security et la bande autorisée sera automatiquement sélectionnée. MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 20: Useful Conventions For Requesting Assistance

    Useful conventions for requesting assistance Conventions Some useful conventions to communicate with Inxpect SpA technical assistance are provided below. Type of application Spatial direction Legend Icon Description Wall installation Ceiling installation MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 21: Perforated Base Dimensions

    Appendix Perforated base dimensions MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA...
  • Page 22 N14 W23777 Stone Ridge Dr., Suite 160, Waukesha, WI 53188 www.magnasphere.com info@magnasphere.com (262) 347-0711 Manufacturer: Inxpect SpA Via del Serpente, 91 MSK-101-MM 25131 Brescia (BS) Installation instructions v1.7 Italy OCT 2018 www.inxpect.com msk-101-mm_instructions_en_us v1.7 security@inxpect.com Copyright © 2017-2018 Inxpect SpA +39 030 5785105...