Stopping The Engine - ABB TPS44-H Series Operation Manual

Turbocharger
Hide thumbs Also See for TPS44-H Series:
Table of Contents

Advertisement

Operation Manual / TPS44-H.. - TPS52-H..
7 Stopping the engine / ​
7

Stopping the engine

Water-cooled turbocharger variant
Post-lubricate as long as the rotor is turning.
u
Observe the oil pressure while performing post-lubrication: 0.5 < p
u
Switch off post-lubrication as soon as the rotor is stationary or after no more than two
u
minutes.
Deviating procedures must be coordinated with ABB Turbocharging.
CAUTION
Water cooling after stopping the engine
If the heat in the turbocharger is not dissipated after the engine stops, dam-
age may result.
Allow the water cooling of the turbocharger to continue operating for 15
u
to 20 minutes after stopping the engine.
© Copyright 2021 ABB. All rights reserved.
HZTL4037_EN
≤1.0.
oil
Rev.F
May 2021