Pentair MT125 Installation And User Manual page 39

Hide thumbs Also See for MT125:
Table of Contents

Advertisement

Connecting the RS-485 Cable from the Heater to the Load Center
MasterTemp COM Pport
Control Panel
Screw Terminal
1 2 3 4
8.
Reinstall the High Voltage Panel: Insert the panel's three tabs into the lower slots on the enclosure.
9.
Secure the panel with the two (2) retaining screws. Close the front door and secure with the latch. See Figure 33 on
page 37.
10. SWITCH ON AC power to the IntelliCenter Control System Load Center.
460906 Rev. D 8/2020
COMMUNICATION PORTS A & B
14 VDC, 2.0A Max. Combined.
®
Connecting IntelliFlo
Pump to IntelliCenter™ Control System COM PORT:
Strip 1/4" insulation from the green and yellow wire conductors.
• Connect the Green wire to pin 2 on Connector J4 or J5.
• Connect the Yellow wire to pin 3 on Connector J4 or J5.
Note: Multiple wires may be inserted into a single terminal.
Optional: COM PORT expansion module (P/N 520818) with 3 extra
COM PORTS up to 2 modules can be installed.
Heater to IntelliCenter wires pin assignment
MasterTemp Heater
COM Port
screw terminal
connector
NOT USED
3 (YELLOW)
2 (GREEN)
1 (BLACK)
Section 1. Installation Instructions
Note: COM PORT A& B
14 VDC, 2.0A Max.
Combined
+15 +DT -DT GND
4
3
2
1
TO HEATER
CONTROL PANEL
RS-485 COM PORT
Figure 36.
IntelliCenter Control System
COM Port (J4 or J5)
MASTERTEMP 125 Pool and Spa Heater Installation and User's Guide
(Continued)
NOT USED
3 (YELLOW)
2 (GREEN)
1 (BLACK)
39