3.4.2. ELECTRICAL CONNECTION

For the direct connection to the electric system it's necessary a device to ensure the disconnection fron the electric system, with a
contacts opening able to disconnect completely the electric system in the conditions of category of over voltage III, in accordance
with installation regulations.
The connection must be done according to the current local regulations. Verify that:
Voltage and frequency correspond to those stated on the data plate of the appliance.
The electrical plant supports the consumption of electricity of the appliance.
The electrical plant has a grounding to the current local regulations.
The appliance must be placed in such a way that the interlocked switched socket-outlets to the network can be easily reached.
Example of type of electric cable:
Cable type
FG7R/FG70R
FG7R/FG70R
FG7R/FG70R
FG7R/FG70R
FG7R/FG70R
FG7R/FG70R
FG7R/FG70R
FG7R/FG70R
When the appliance is operating, the power supply voltage must not diverge from the value of the nominal voltage, indicated on
the data plate, by more than ± 10 %.
Gas ovens are equipped with cable and Schuko plug (single phase 230 V).
Insert the plug in the socket only if you are sure that the socket is right for the plug. Three phases ovens are not supplied with
electrical cable, therefore it is necessary to connect to the oven internal terminal board a cable of proportionate section.
Cable replacement: after opening the lower cover, placed in back side of the oven (unscrew the fixing screw), connect the
conductives in accordance with the selected wiring diagram. Fix the cable to the suitable cable gland and close the back cover.
The connection or replacement of the cable has to be done by authorized personnel.
If the cable is damaged it has to be sustituted by authorized personnel.
3.4.2.1. EQUIPOTENTIAL SYMBOL
EQUIPOTENTIAL CONNECTION: it's necessary when different appliances have to be connected (electrical or neutral) in an equipotential
system.
B1
D= INTERCETTATORE
COCK
C
TANICA DETERSIVO
DETERGENT TANK
Ø (mm²)
5x10
5x6
5x6
5x4
5x4
5x2,5
5x2,5
3x2,5
19
kW electric
36
27
24
18
12
6
9
3,2
A1