Remedy Of Faults; Maintenance And Cleaning; Cleaning The Container; Replacing The Aerator Stone - Oase ProfiClear Premium XL Moving Bed Modul Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
6

Remedy of faults

Malfunction
No flow of water
Water flow insufficient
Water contains too much
ammonia/nitrite.
Pond Pads are flushed out
Reduced movement of the
Pond Pads
Only minor movement of
the Pond Pads
7

Maintenance and cleaning

Dead biomass drops to the bottom and has to be removed. To do this, open the DN 75 dirt outlet for
approx. 10 seconds.
• The entire filter system only needs to be taken out of operation for cleaning and maintenance if it is
extremely soiled.
• Do not use any chemical cleaning agents as they would kill the filter bacteria.
7.1

Cleaning the container

How to proceed:
1. Switch off all filter pumps.
2. Switch off all other electrical units of the filter system (e.g. UVC clarifier).
3. Gravity fed systems only: Close the slide valves (supply and return) of the filters connected in series
to prevent further water flow.
4. Open the slide valve for the DN 75 dirt outlet at the bottom of the container and dispose of the
soiled water in a permissible way.
5. Carry out cleaning measures.
– Rinse the Pond Pads in the container with running water.
6. Close the slide valve (dirt outlet).
7. Start up the filter system again. (→ Commissioning/start-up)
7.2

Replacing the aerator stone

How to proceed:
 E
1. To increase visibility of the aerator stone, remove approx. ⅔ of the Pond Pads and store in a moist
area. After completing the maintenance work, return the Pond Pads to the container.
2. Pull the aerator stone out of the clamping holder.
3. Disconnect the hose from the aerator stone and connect it to the new aerator stone.
– Fasten the connecting hose with a hose clip.
4. Push the aerator stone back into the clamping holder.
Possible cause
Filter pump is not switched on
Supply to filter system or return to pond is
blocked.
Bottom drain, pipe or hose is blocked
Hose is kinked
Excessive loss in lines
Too few Pond Pads used
Unit has only been in operation for a short
time
Meshed tube has slipped
Meshed tube is defective
Aerator stone is clogged
Pond aerator malfunction
Pond Pads are not yet fully colonised
Remedy
Switch on the filter pump, connect the power plug.
Clean the supply and/or return.
Clean, replace if necessary.
Check hose, and replace if necessary.
Reduce line length to necessary minimum.
If necessary, add more Pond Pads
The full biological cleaning effect is only achieved
after several weeks.
Correct the position of the meshed tube
Replace the meshed tube
Replace aerator stone
Check pond aerator
Wait, as bacterial colonisation is a natural pro-
cess and takes several weeks.
- EN -
21