M-wrg-s series;5016 series;5014 series.
home ventilation with heat recovery
.
for surface-mount and flush-mount installation
of m-wrg ventilation units (32 pages)
Page 1
Ventilation unit M-WRG-S/Z-T(-F,-FC) M-WRG-S/Z-T(-F,-FC)-FU CO ² Part no. 5302-22 07/2015 EN VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 · D-82239 Alling info@meltem.com · www.meltem.com...
Controls on the ventilation unit ..................17 InControl pushbutton sensor ..................17 7.2.1 InControl pushbutton sensor for the type M-WRG-S/Z-T ventilation unit ....... 17 VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH & Co. KG Am Hartholz 4 ·...
Page 3
V E N T I L AT I O N & H E AT R E C O V E R Y 7.2.2 InControl pushbutton sensor for the type M-WRG-S/Z-T-F ventilation unit ....18 7.2.3 InControl pushbutton sensor for the type M-WRG-S/Z-T-FC ventilation unit ....18 Wireless remote control M-WRG-FUFB .................
Page 4
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH &...
M-WRG-S stands for Meltem heat recovery standard unit. Home ventilation expertise extending back over 30 years has been incorporated into this product from Meltem Wärmerückgewinnung. Using windows for ventilation, particularly during periods of cold weather, is now a thing of the past.
2). The LEDs integrated into the pushbutton sensor indicate the currently selected ventilation program. Up to five ventilation units of the same type can be controlled with one InControl pushbutton sensor. The ventilation unit M-WRG-S/Z-T-F also has a humidity control program. In addition to the humidity control, the M-WRG-S/Z-T-FC also has an integrat- CO ²...
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y EC Declaration of Conformity The ventilation units described below Type: Part number...
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y Technical data 1.7.1 Electrical connection Operating voltage 230 V AC Mains frequency...
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y Condensate drainage Via exhaust air pipe, no condensate trap required Fully automatic cover flap control when switching...
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y Safety instructions This manual contains notes that you must follow for your own personal safety and to avoid injury and damage to property.
(e.g. model-making) or corrosive gas emissions (e.g. blueprint shop, cleaning). — For any use contrary to the intended use, Meltem Wärmerückgewinnung GmbH & Co. KG shall accept no liability for any damage that may occur and offers no warranty that the components will work perfectly and correctly.
The installation kit was not installed as described in the installation manual. — The ventilation unit was not installed as described in the installation manual. — Genuine Meltem parts were not replaced with genuine parts. — Unapproved changes were made to the installation kit or ventilation unit. —...
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y Structure and function Overview of the modules 5.1.1 Ventilation unit – cover attached...
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y Description of the functions 5.2.1 How the M-WRG ventilation unit works The supply air fan (item 5 in Fig.
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y 5.2.2 How the cross-flow plate heat exchanger works The warm extract air (item 5 in Fig. 11) drawn in from the interior is routed through the chambers of the cross-flow plate heat exchanger (item 1 in Fig. 11) and heats them.
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y Operation at cold times of year NOTE ► During cold times of year, run the ventilation unit in continuous mode.
The InControl pushbutton sensor allows you to select one of six different ventilation programs. The available ventilation programs depend on the type of ventilation unit. Every button has an LED that indicates the currently selected ventilation program. 7.2.1 InControl pushbutton sensor for the type M-WRG-S/Z-T ventilation unit Reduced Normal ventilation...
M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y 7.2.2 InControl pushbutton sensor for the type M-WRG-S/Z-T-F ventilation unit Reduced Normal ventilation...
NOTE — Note that the button for the “Humidity control” ventilation program is only assigned on the M-WRG-S/Z-T-F-FU and M-WRG-S/Z-T-FC-FU ventilation unit types. — Note that the button for the “CO control / Air quality” ventilation program is only assigned on the M-WRG-S/Z-T-FC-FU ventilation unit type.
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y Starting up Check ventilation unit before switching on for first time ►...
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y Connect wireless remote control M-WRG-FUFB to ventilation unit (for M-WRG-S/Z-T(-F, -FC)-FU only) When the ventilation unit is started for the first time, a connection must be established between the ventilation unit and the wireless remote control.
NOTE ► Note that the button for the “Humidity control” ventilation program is only assigned on the M-WRG-S/Z-T-F-FU and M-WRG-S/Z-T-FC-FU ventilation unit types. ► Note that the button for the “CO control / Air quality” ventilation program is only as- signed on the M-WRG-S/Z-T-FC-FU ventilation unit type.
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y Ventilation programs There are different ventilation programs available for selection, depending on the type of ventila- tion unit. The individual ventilation programs are identified by symbols on the InControl pushbutton...
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y 10.6 “Exhaust air operation” ventilation program Exhaust air operation with limited heat recovery. This operating mode can be...
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y Filter maintenance The level of soiling of the round filter cartridges is automatically monitored by the ventilation unit. A pending filter change is signalled audibly roughly 2 to 3 weeks in advance. As the time for the filter change approaches, the intervals between the audible warnings shorten. The filters must be changed when the warning signal occurs every hour and lasts for one second. This long warning period allows the user to order replacement filters in good time. No tools are needed to change the filters. 11.1 Choice of filter There are several filter classes available for the ventilation unit M-WRG-S/Z-T...:...
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y 11.3.1 Remove cover from ventilation unit ► Using both thumbs, press the two latches (item 1 in Fig.
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y 11.3.3 Insert new filters ► Carefully guide the extract air filter into the ventilation unit. ► Make sure that the filter slides into the four retaining tabs (item 1 in Fig. 21) on the back wall of the ventilation unit.
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y Cleaning WARNING ► Switch off the power to the ventilation unit before cleaning.
Page 29
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y Space for notes VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH &...
Page 30
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y Space for notes VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH &...
Page 31
Operating instructions M-WRG-S/Z-T(-F,-FC) / M-WRG-S/Z-T(-F,-FC)-FU ventilation unit V E N T I L AT I O N & H E AT R E C O V E R Y Space for notes VE NT I LAT I O N TH E R IG HT W AY Meltem Wärmerückgewinnung GmbH &...
Need help?
Do you have a question about the M-WRG-S/Z-T and is the answer not in the manual?
Questions and answers