2) INSTALL MODULE IN CHASSIS AND CONNECT CABLES
a. Carefully slide the module into an open slot in the chassis. Align the module with
the installation guides and ensure that the module is firmly seated against the
backplane. Secure the module by fastening the front panel thumbscrew (push in and
turn clockwise to tighten) to the chassis front. Verify the "Pwr" LED is ON (indicating
the chassis/module is powered).
b. When using the SFP model (8719-0 or 8739-0), insert the SFP fiber transceiver into
the SFP receptacle on the T1/E1 converter (see the SFP Data Sheet 091-17000-001
for supported 100M transceivers).
NOTE: The release latch of the SFP Fiber transceiver must be in the closed
(up) position before insertion.
c. Connect to the RJ-45/48 connector on the module via a Category 3 or better cable
(Category 5 is recommended), and attach the other end to the network equipment.
d. Connect an appropriate multimode or single-mode fiber cable to the fiber port of the
installed module. It is important to ensure that the transmit (TX) is attached to the
receive side of the device at the other end and the receive (RX) is attached to the
transmit side. Single-fiber (SF) media converter models operate in pairs. The TX
wavelength must match the RX wavelength at the other end and the RX wavelength
must match the TX wavelength at the other end.
CABLE SPECIFICATIONS
UTP Cable for T1 and E1
Gauge
Impedance
Impedance Characteristics
Maximum Distance
Coax Cable for E1
Gauge
Impedance
Impedance Characteristics
Maximum Distance
22 to 24 AWG
T1: 100 ohms +/- 10%
E1: 120 ohms +/- 10%
2.6 dB / 100M @ 1MHz
T1: 6,000 ft
E1: 8,000 ft
22 to 24 AWG
75 ohms +/- 10%
2.0 dB / 100M @ 1MHz
8,000 ft
Page 7
3) VERIFY OPERATION
Once the module has been installed and configured per steps 1 and 2, verify the module
is operational by viewing the LED indicators.
The Power LED indicates the module is receiving power.
The Fiber Optic link LED indicates the fiber optic connection has been established.
The UTP LED indicates a T1/E1 signal has been detected.
If the Fiber Optic LED is blinking, the port is receiving an all 1s signal. This will occur
if the UTP port is not connected.
LED Function
Color
OFF State
"Legend"
Power
Amber
No power
"Pwr"
Fiber
Green
No signal detected
"F/O Lk"
Test
Amber
No signal detected
"Tst:
RJ-45/48
Green
No signal detected
"UTP Lk"
SPECIFICATIONS
Description
iConverter T1/E1
T1 or ISDN PRI: 1.544Mbps
Data Rates
E1: 2.048Mbps
ANSI: T1.403, T1.102
AT&T: T62411
Standard Compliances
ITU:
G.703, G.704, G.706, G.736, G.755, G.823
ETSI: ETS 300 166
UL, CE, FCC Class A,
Regulatory Compliances
RoHS, WEEE, REACH
Category 3 or better
Balanced twisted pair copper
(T1: 100 Ohm cable termination, E1: 120 Ohm cable termination)
Cable
(Active Pairs are Pins 1, 2 and 4, 5)
75 Ohm coax cable for unbalanced E1 connection
DC Power Requirements
3.3VDC, 0.7A @ 3.3VDC
Dimensions
0.85" x 4.5" x 2.8" (21.6 mm x 114.3 mm x 71.1 mm)
W x D x H
Weight
8 oz. (226.8 grams)
Commercial:
Temperature
Wide:
Storage:
Humidity
5 to 95% (non-condensing)
Altitude
-100m to 4,000m
MTBF (hrs)
580,000
Warranty
Lifetime warranty
ON / Blinking State
ON: Power is applied
ON: Signal detected
Blinking: All ones signal received
ON: Loop or All Ones Test Mode
Slow Blinking: FOT received - Local
Fast Blinking: FOT received - remote
ON: Signal detected
Blinking: All ones signal received
0 to 50°C
-40 to 60°C
-40 to 80°C