Omnitron Systems iConverter XG User Manual

Advertisement

iConverter
XG
®
User Manual
38 Tesla, Irvine, CA 92618 USA
Phone: (949) 250-6510; Fax: (949) 250-6514
General and Copyright Notice
This publication is protected by U.S. and international copyright laws. All rights
reserved. The whole or any part of this publication may not be reproduced, stored
in a retrieval system, translated, transcribed, or transmitted, in any form, or by
any means, manual, electric, electronic, electromagnetic, mechanical, chemical,
optical or otherwise, without prior explicit written permission of Omnitron Systems
Technology, Inc.
The following trademarks are owned by Omnitron Systems Technology, Inc.:
FlexPoint
, FlexSwitch
, HybridNID
TM
TM
OmniLight
, OmniConverter
, RuggedNet
®
®
OST
and the Omnitron logo.
TM
All other company or product names may be trademarks of their respective owners.
The information contained in this publication is subject to change without notice.
Omnitron Systems Technology, Inc. is not responsible for any inadvertent errors.
Warranty
This network product and the included AC/DC power adapter are warranted to the
original purchaser (Buyer) against defects in material and workmanship for a period
of two (2) years from the date of shipment. The warranty for the network product
can be extended to lifetime by registering the product at www.omnitron-systems.
com/support within ninety (90) days from the date of shipment. During the warranty
period, Omnitron will, at its option, repair or replace a product which is proven to be
defective with the same product or with a product with at least the same functionality.
For warranty service, the product must be sent to an Omnitron designated facility,
at Buyer's expense. Omnitron will pay the shipping charge to return the product
to Buyer's designated US address using Omnitron's standard shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to product malfunctions resulting from
improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer-
supplied equipment, Buyer-supplied interfacing, unauthorized modifications or
tampering with equipment (including removal of equipment cover by personnel not
specifically authorized and certified by Omnitron), or misuse, or operating outside
the environmental specification of the product (including but not limited to voltage,
ambient temperature, radiation, unusual dust, etc.), or improper site preparation
or maintenance.
No other warranty is expressed or implied. Omnitron specifically disclaims the implied
warranties of merchantability and fitness for any particular purpose.
The remedies provided herein are the Buyer's sole and exclusive remedies. Omnitron
shall not be liable for any direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal theory.
Environmental Notices
The equipment covered by this manual must be disposed of or recycled in
accordance with the Waste Electrical and Electronic Equipment Directive (WEEE
Directive) of the European Community directive 2012/19/EU on waste electrical and
electronic equipment (WEEE) which, together with the RoHS Directive 2015/863/
, iConverter
, miConverter
, NetOutlook
®
®
TM
, Omnitron Systems Technology, Inc.
®
Page 2
,
®
,
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iConverter XG and is the answer not in the manual?

Questions and answers

Summary of Contents for Omnitron Systems iConverter XG

  • Page 1 Omnitron Systems Technology, Inc. The following trademarks are owned by Omnitron Systems Technology, Inc.:...
  • Page 2 Product update for firmware revision 1.1.4. Operational change to the self-diagnostic circuit test. The iConverter XG (8599P-xx) is a protocol-transparent fiber media converter The equipment is marked with the WEEE symbol shown to indicate that it with two pluggable transceiver ports supporting data rates from 6G to 11.32G and must be collected separately from other types of waste.
  • Page 3: Link Modes

    1) CONFIGURE DIP-SWITCHES SW3, SW4 - Reserved The location of the DIP-switches is shown below. These switches are reserved and must be in the LEFT/DOWN default position. DIP-SWITCH BANK 2 The function of DIP-switch Bank 2 is outlined in the table below. Function DOWN DOWN...
  • Page 4: Installing The Module

    A successful test will produce a green blinking (5Hz) P1 LB LED on the local XG 3) APPLY POWER and a green blinking (1Hz) P1 LB LED on the remote XG. If the local XG does AC Power - Standalone Modules not receive a valid response, the P1 LB LED will be blinking amber (5Hz).
  • Page 5: Connect Cables

    WARNING!!! WARNING: Only a DC power source that complies with safety extra low voltage (SELV) requirements can be NEVER ATTEMPT TO OPEN THE CHASSIS OR connected to the DC-input power supply. SERVICE THE POWER SUPPLY. OPENING THE CHASSIS MAY CAUSE SERIOUS INJURY OR DEATH. THERE ARE NO USER REPLACEABLE OR SERVICEABLE PARTS IN THIS UNIT.
  • Page 6: Verify Operation

    5) VERIFY OPERATION SPECIFICATIONS Once the module has been installed and configured per steps 1 and 2, verify the iConverter Description module is operational by viewing the LED indicators. Protocol-Transparent Media Converter/Transponder IEEE 802.3ae (10G Ethernet), The XG does not generate data, it only passes the data it receives from the SONET OC-192, SDH STM-64, connected equipment.

Table of Contents