Smartswitch STS-220 Setup Instructions

Deluxe programmable toilet controller
Hide thumbs Also See for STS-220:

Advertisement

Quick Links

Smartswitch Toilet Controller
Model: STS-220
The unique Deluxe Programmable Toilet Controller by Smartswitch was designed for all
electric marine toilets with remote, fresh or salt water flushing supply via an inlet pump or
water solenoid valve. The stylish control panel provides fully automatic programmed
flushing when the Flush touch pad is pressed. It also provides independent operation of
the inlet or discharge pumps for maintenance or line clearance when the manual touch
pads are used. In-built troubleshooting features and toilet pump protection are standard.
When pressed the
system will activate
a complete flush
cycle automatically.
If the tank system is
connected, this light will
turn on when the Holding
Tank is full and disable
any further flush cycles.
This Product has been Factory Preset to operate effectively without
Should you wish to alter these settings please follow proceeding
making any further adjustments.
instructions.
Water will be added
while the button is
held down.
(Max 20 seconds)
The extraction motor
will run while the
button is held down.
(Max 20 seconds)
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the STS-220 and is the answer not in the manual?

Questions and answers

Summary of Contents for Smartswitch STS-220

  • Page 1 Smartswitch Toilet Controller Model: STS-220 The unique Deluxe Programmable Toilet Controller by Smartswitch was designed for all electric marine toilets with remote, fresh or salt water flushing supply via an inlet pump or water solenoid valve. The stylish control panel provides fully automatic programmed flushing when the Flush touch pad is pressed.
  • Page 2 Programming This product has three Model Modes of operations: Model Mode 1 = Standard Mode Model Mode 2 = Tecma Silence (Series) Model Mode 3 = Tecma Prestige (Series) Model Mode 4 = European Mode This product has been factory default set to Model Mode 2 (see page 4) Factory Default: T1 = 20 seconds Model Mode = Tecma Silence (Series)
  • Page 3 Programming for Standard Model Mode 1 Step 1 – Placing the unit in program mode: After wiring and applying power, hold the Water Only & Empty Only buttons down together for 3 seconds. The Holding Tank Full LED will give three quick flashes indicating you have entered program mode.
  • Page 4 Programming for Tecma Silence (Series) Model Mode 2 Step 1 – Placing the unit in program mode: After wiring and applying power, hold the Water Only & Empty Only buttons down together for 3 seconds. The Holding Tank Full LED will give three quick flashes indicating you have entered program mode.
  • Page 5 Programming for European Model Mode 4 Step 1 – Placing the unit in program mode: After wiring and applying power, hold the Water Only & Empty Only buttons down together for 3 seconds. The Holding Tank Full LED will give three quick flashes indicating you have entered program mode.
  • Page 6 Model Timing Chart This device has three different timing sequences, any one may be selected. (Factory default is Model Mode 2 = Tecma Silence) Mode 1: Standard Model Mode 1 Start Water Inlet Discharge Motor Water Inlet Programmable Programmable Programmable 2 sec’s 2 sec’s from 1 - 20 sec’s...
  • Page 7 Programming the Device for Model Mode or Disable Features Place the unit in Model Mode / Disable Features Program Mode: Hold the Water Only & Empty Only buttons down together for 3 seconds. The Holding Tank Full LED will give three flashes indicating you have entered program mode. While still holding down these two buttons, press the Normal Flush button.
  • Page 8 Programming Flow Chart Hold the Water Only & Empty Only buttons down together for 3 seconds (LED will give three flashes) While still holding down these two buttons, press the Normal Flush button Push Normal Flush (LED will give six flashes) Tecma Silence Series Push Normal Flush Push Empty Only...
  • Page 9 Operating Instructions: Normal Flush: Pressing the Normal Flush button will run the auto cycle (see page 6 for details). Water Only: While this button is held down the water valve/inlet pump will activate (Maximum 20 seconds per press). After activation this button will be disabled. The Empty Only button will need to be pressed for at least 1 second to reactivate this button.
  • Page 10 Connections Toilet Control Flush Tank Full Float Switch Battery Negative FIG 1 Water Inlet Pump/Valve - Discharge Pump - EST + (Not used) Water Inlet Pump/Valve + Discharge Pump + Battery Positive...
  • Page 11: Fitting Instructions

    Fitting Instructions “ Warning ” This device should be fuse protected and mounted in a dry area as close to the Toilet as is practical. DO NOT cover the ventilation slot on the top of this device. If the keyboard is mounted in an area where it may experience moisture or wetting, please ensure that a bead of silicon is placed around the keyboard to waterproof it.