14.TROUBLESHOOTING GUIDE
Before requesting service, please check your stopwatch following the table below.
Problem
Possible cause
Solution
The  motor  does  not  run 
●Weak batteries. 
●Replace  the  batteries 
even  if  the  power  switch 
 
 with new ones. 
of  the  printer  is  turned 
●The  batteries  are  not 
●Install  the  batteries   
"ON".
 installed properly. 
 properly. 
 
 
●The paper is stuck. 
●Remove the paper.
 
The 
paper 
is 
not 
●Weak batteries. 
●Replace  the  batteries 
advanced  by  pressing 
 
 with new ones. 
the  paper  advancing 
●The paper is stuck. 
●Remove the paper. 
switch.
 
 
●The roll paper gets out 
●Make  the  roll  paper 
 of shape.
 round.
By  pressing  the  start 
●The  cord  is  not  con-
●Connect 
button,  the  paper  is 
nected properly. 
correctly. 
advanced, 
but 
the 
●Water 
or 
foreign 
●Wipe  off  the  water  or 
printed  digits  or  letters 
matters  are  sticking  to 
foreign matters. 
are  detective  or  the  data 
the cord  plug. 
 
are not printed at all.
●The  paper  is  not  set 
●Inset 
properly.
properly.
73
全国共通フ リーダイヤル  
お客様相談室 
〒 
100-0005 
東京都千代田区丸の内  3-1-1  国際ビル 
 
〒 
550-0013
大阪市西区新町 1-4-24  大阪四ツ橋新町ビルディ ング 
本 社 〒105-8467  東京都港区虎ノ門2-8-10
http://www.seiko-watch.co.jp/
Problem
Possible cause
By  pressing  the  start 
●The paper is stuck. 
button,  the  data  are 
 
printed out, but the paper 
●Weak batteries.
is  not  advanced  irregu-
larly.
By  pressing  the  start 
●Weak batteries. 
button,  no  data  are 
 
printed out and the paper 
●The  batteries  are  not 
is not advanced at all.
 installed properly. 
 
●The  power  switch  of 
 the  printer  is  not  set  to 
 "ON".
the 
cord 
●The cord is not connect-
Auto  start  time  is  not 
transferred.
 ed properly. 
 
●Water or foreign matters 
the 
paper 
 are  sticking  to  the  cord 
 plug.
*For the solution of trouble other than the above, contact the retailer from whom the watch was purchased.
0120-612-911

15.SPECIFICATIONS

(Stopwatch)
Solution
1.Frequency of crystal .....................32,768Hz  (Hz=Hertz...Cycles  per
oscillator
2.Loss/gain ....................................Less  than  15  seconds  at  normal
●Remove the paper. 
(monthly rate)
 
3.Operational temperature ...............−10℃〜+60℃
●Replace  the  batteries 
range.
Desirable temperature  ..................0℃〜+50℃
 with new ones.
range of use
4.Display system ........................... Stopwatch  display Measures  up  to
●Replace  the  batteries 
 with new ones. 
●Insert 
the 
batteries 
 correctly. 
 
●Turn  the  power  switch 
 "ON", and then press the 
 start button.
5.Display medium ...........................Nematic  Liquid  Crystal,  FEM  (Field
●Connect  the  cord  prop-
6.Battery .......................................Lithium battery SB-T74, 1 piece
 erly. 
7.Battery Life .................................A  new  normal  battery  will  last
 
●Wipe  off  water  or  for- 
 eign matters.
8.IC (Integrated Circuit) ...............C-MOS-LSI, 1 piece
9.Battery life indicator ..............."BATT"  mark  start  flashing  when
(Printer)
1.Printer .................................Model: MTP102
second)
temperature range (5℃〜35℃)
10  hours.  Hour,  minutes,  seconds,
1/100  seconds,  tnree-row  display  of
2.Recording paper .....................Roll paper S-950
split  time/lap  time/total  elapsed  time  or
lap time in progress. No. of blocks, no.
of  split  times  (0〜999),  300  memory
recall,  BLOCK,  SPLIT,  LAP,  STOP,
RECALL,  stopwatch  marks,  memory
3.Power supply ........................DC  6.0V  (SUM-3  or  AM3  dry
indicator, BATT.
Time/calendar  display Hour  (24hour
indication),  minutes,  seconds,  year,
month, date and calendar mark, ID no.
(OFF/01〜99),  contrast  adjustment
4.Power consumption ...............During  printing:  Approx.  1.5W  (DC
display.
Auto  start  set  display AS,  OFF,  ON,
5.Battery life
...........................Manganese  battery:  Approx.
hour,  minutes,  seconds,  1/100
seconds, auto start set mark.
Effect Mode)
approximately three years.
6.Operational temperature range...0℃〜40℃ (The  depth  of  printout
If  the  stopwatch  is  used  for  more  than  3
hours  a  day,  the  battery  life  may  be  less
than 3 years.
*The  above  specifications  are  subject  to  change  without  prior  notice,  for
product improvement.
the battery life nears its end.
Printing  system:  Thermal  serial  dot
printing system
Printing  method:  One-way  printing
(from left to right)
Printing  speed:  Approx.  1.5
lines/sec. (DC 5 0V. at 25℃)
Number  of  digits  printed:  13
digits/line (including space)
38mm  (width)  (+ 0〜 0.5mm),
overall  length  2,400  mm  or  more
(approx.  700  lines  can  be  printed
per roll.)
battery, 4 pieces)
With power switch turned "ON" (No
printing) : Approx. 0.02W (DC 6.0V)
6.0V)
10,000  lines  can  be  printed.
(Equivalent to approx. 14 rolls)
Alkaline  manganese  battery:
Approx.  20,000  lines  can  be
printed.  (Equivalent  to  approx.  28
rolls)
does  not  change  even  if  the
temperature changes.)
74