Printout of lapse of time
・In addition to the elapsed time, the stopwatch can print out the
time when the lap time is measured.
・The time a lap time is measured is not stored in memory.
□
Turn on the power switch for printer and then press mode
1
selection button②(TIME) to set the stopwatch to the
time/calendar mode.
POWER
ON
(1)Turn on the power switch.
(2)Press mode selection button ③
(TIME) to set the stopwatch to
the time/calendar mode.
SYSTEM STOPWATCH
300LAP/SPLIT MEMORY
SPLIT
F
BLOCK
LAP
STOP
BATT .
LAP
E
RECALL
STOP-W. A/S SET TIME
LOCK
CLEAR
LAP/SPLIT
START
RESET
STOP
1/100
STOP.W A/S SET
TIME
RECALL
57
7.HOW TO USE THE AUTO START FUNCTION
Auto start function: By presetting the time when the measurement is
started, the stopwatch automatically starts measuring at the designated
time. This function is very convenient for a competition like marathon, where
the race starts at a fixed time. In addition, the designated starting time can
be transferred to other stopwatches such as Cal. S143 and thus the
measurement can be started simultaneously at different checkpoints.
1.Auto start time setting (how to set the starting
time)
1
□
Press the mode selection button ② (A/S SET) to set the
stopwatch to the auto start setting mode .
Indicates that the
SYSTEM STOPWATCH
300LAP/SPLIT MEMORY
auto start function
SPLIT
F
BLOCK
is deactivated.
LAP
STOP
BATT .
LAP
E
RECALL
STOP-W. A/S SET TIME
LOCK
SPLIT
CLEAR
LAP/SPLIT
START
RESET
STOP
Auto start time
BLOCK
1/100
STOP.W A/S SET
TIME
LAP
STOP
RECALL
BATT .
LAP
RECALL
Mode selection
Auto start setting mode mark
button ② (A/S
SET)
59
*Please note that the time of measurement cannot be printed out
unless the stopwatch is reset to "00".
Stopwatch
Time/calendar
mode
mode
SPLIT
ID
F
BLOCK
BLOCK
LAP
LAP
STOP
STOP
BATT .
BATT .
LAP
LAP
E
RECALL
RECALL
2
□
Set the auto start time.
Minute setting
Hour setting
Press button ○
B
, and the minute digits start flashing.
Press button ○
B
, and the hour digits start flashing.
Press button ○
A
to set the digits. With each press of
Press button ○
A
to set the digits. With each press
the button, one minute is advanced.
of the button, one hour is advanced.
SPLIT
SPLIT
BLOCK
BLOCK
LAP
LAP
STOP
STOP
BATT .
BATT .
LAP
LAP
RECALL
RECALL
LAP/SPLIT
START
LAP/SPLIT
RESET
STOP
RESET
B
○
○
A
B
○
*The digits move quickly if the button is kept pressed.
NOTES : When you press button ○
B
to start setting the auto start time,
all the stored data is cleared.
□
Press button ○
to start the printout. With each press of button
2
A
B
○
, the time when the lap time is measured is printed out. To
stop the printout, press button ○
SYSTEM STOPWATCH
300LAP/SPLIT MEMORY
SPLIT
BLOCK
LAP
STOP
BATT .
LAP
RECALL
STOP-W. A/S SET TIME
LOCK
Button ○
B
CLEAR
Printout of the
LAP/SPLIT
START
RESET
STOP
time when the
1/100
STOP.W A/S SET
F
lap time is
RECALL
measured.
E
3
□
Enter the auto start time.
Setting
After setting the auto start time, press button ○
The digits stop flashing and the auto start time set has
been entered in memory.
SPLIT
Indicated that the auto start
function is activated.
BLOCK
LAP
Auto start time (10:05)
STOP
BATT .
LAP
RECALL
START
LAP/SPLIT
START
STOP
RESET
STOP
c
○
A
○
B
A
Identification number is printed when it is set
ID:1
1999 10 10
−− −−Year, Month, Date
ST-10:10'00
−− −−Starting time (10:10'10'')
1-10:10'21
−− −−1st lap time (10:10'21'')
2-10:10'25
−− −−2nd lap time (10:10'25'')
F
3-10:10'26
−− −−3rd lap time (10:10'26'')
4-10:10'28
−− −−4th lap time (10:10'28'')
E
5-10:10'33
−− −−5th lap time (10:10'33'')
6-10:10'36
−− −−6th lap time (10:10'36'')
Button ○
A
7-10:10'39
−− −−7th lap time (10:10'39'')
Start/stop
8-10:10'50
−− −−8th lap time (10:10'50'')
TIME
9-10:10'59
−− −−9th lap time (10:10'59'')
10-10:11'03
−− −−10th lap time (10:11'03'')
/S/10:11'06
−− −−Finish time (10:11'6'')
*The time is printed out in the 24-hour indication.
□
4
After the auto start time is entered in memory, press
button ① (STOP. W) to return to the stopwatch mode .
Return to the stopwatch mode.
B
again.
Be sure to confirm the third line display changes
to the current time. If not, auto start function
doesn't become effective.
SYSTEM STOPWATCH
300LAP/SPLIT MEMORY
SPLIT
F
BLOCK
LAP
STOP
BATT .
LAP
E
RECALL
STOP-W. A/S SET TIME
LOCK
CLEAR
LAP/SPLIT
START
RESET
STOP
1/100
STOP.W A/S SET
TIME
RECALL
mode selection button ① (STOP.W)
58
Auto start time
SPLIT
BLOCK
LAP
Current time
STOP
BATT .
LAP
RECALL
*The stopwatch starts measuring at the
designated auto start time with three beeps.
*To cancel the auto start time set in the procedure
60
above, press mode selection button ② (A/S SET).