At Trouble
The watch temporarily 
gains or loses time.
The watch displays an incorrect time 
hour unit, even though it displays the 
Misalignment 
precise time of minutes and seconds
of the time and 
The  reception  results  are 
hand positions
successful, but the precise 
time is not displayed.
T h e   s e c o n d   h a n d 
7
position  is  not  correctly 
aligned in  the reception 
results  display   or  the 
reception level display.
138
At trouble
  T he  buttons  or  crown 
cannot  be  activated 
(operated).
Operation
  F o r g e t   s t e p   i n   t h e 
middle  of  the  setting 
procedures.
Others
Blur on the dial glass persists. Water has gotten inside the watch due to deterioration of the packing.
※ For the solution of troubles other than the above, consult the retailer from whom the watch was purchased.
7
140
Possible causes
The watch fails to receive a radio signal correctly as 
a result of external infl  uence (incorrect reception).
The watch has been left in an extremely high or 
low temperature place for a long time.
The  watch  may  be  set  to  a  time  in  a  different 
time  zone  from  the  region  where  the  watch  is 
currently used.
The hand positions were misaligned as a result of external infl  uence.
The hands are out of the preliminary position as a result of external infl uence. 
→ Preliminary Position on page 132
The  second  hand  is  out  of  the  preliminary 
position as a result of external infl  uence. 
→ Preliminary Position on page 132
Possible causes
The stored energy is running short.
−−−−−−−−−−−−−−−−−−−−−−−−
Solutions
1. Place the watch where it is able to receive a radio signal more easily. 
2. Conduct manual reception if necessary.
1. When the watch returns to a normal temperature, it will display the precise time as before.
2. If the watch still gains or loses the time, conduct manual reception if necessary.
3.   I f the watch cannot resume normal movement even after conducting the above mentioned 
procedures, consult the retailer from whom the watch was purchased.
Check the time zone that the watch is currently set for, and select the 
time zone to Tokyo (Japan).
1.   N o  crown  or  button  operation  is  needed,  since  the  automatic  hand  position 
adjustment  function  will  be  activated  to  align  the  hand  positions.  Automatic 
Hand Position Alignment Function activates once a minute for the second hand 
and at 12:00 both for the AM and PM for the minute and hour hands.
2.   I f the watch still gains or loses time, refer to  In Case of an Abnormal Movement  
to perform procedures.
3.   I f the watch cannot resume normal movement even after conducting the above 
mentioned procedures, consult the retailer from whom the watch was purchased.
Solutions
Fully charge the watch so that the second hand may move at one-second intervals. Page 98
1. When the crown is pulled out, push it back in.
2. Leave the watch untouched for a while. The watch will resume its normal movement.
3. Then start the setting procedure from the beginning.
Consult the retailer from whom the watch was purchased.