Display Illumination; Functions Of The Keys; Menu Navigation And Configuration - ZILA KST-20 Vento Mounting And Operating Instructions

Climate controller
Table of Contents

Advertisement

Climate Controller KST-20 Vento | KST-20 Vento/CO2 | KST-20 Vento/RN

6.2. Display illumination

If no key is pressed on the control unit for longer
than 1 minute, the air conditioning control unit
automatically switches off the background lighting
of the display. Pressing any function key switches,
the display lighting back on.

6.3. Functions of the keys

All four operating keys on the device are basically
equipped with at least two functions. One is the
function which is illustrated on the key and the
other is the function described by the text below the
key.
Key „Trend "
In the dehumidifying mode, pressing the TREND key
resets the trend value, i.e. the current value for the
absolute humidity in the interior is stored as a
reference
value
dehumidification success. This should be done after
the unit has been put into operation. The
dehumidification success can be checked later
during normal operation by pressing the PAUSE key.
If, however, the timer is active, it is deactivated by
pressing the TREND key.
Observe operating mode!
Tendency reset and deactivation of the
timer refer to the dehumidification
.
operating mode
On the first level of the configuration menu,
pressing the TREND key takes you back to the menu
item „Start measurement".
for
the
subsequent
Key „Mode "
In normal operation, a manual ventilation process
can be started by pressing the MODE button.
In the configuration menu, the MODE key can be
pressed to scroll to the left.
When the device is switched on, pressing the MODE
button takes you to the factory settings.
Key „Pause "
During normal operation, the automatic mode can
be interrupted with the PAUSE key. The display will
then show the stored reference value for absolute
humidity with the corresponding date and, on the
second line of the display, the current value for the
absolute humidity in the interior.
Key „Enter "
Press the ENTER key to open the configuration
menu and confirm the entries made within the
menu.
If the menu item "Start measurement" is confirmed
by pressing ENTER, the instrument exits the menu
and changes to the automatic mode.
6.4. Menu navigation and
configuration
The selected operating mode is indicated in the unit
display by the letters E for dehumidification, L for
ventilation and K for cooling.
In addition, the selected actuator system is
indicated at the end of the second line by the
corresponding character.
Handbook Version: ENG_05052020_ANHU_KST20VENTO|