7: Finally, close the housing cover panels (1) on the
left and right edges.
8: Connect the outdoor climate sensor to the
corresponding socket on the right side of the
bottom of the housing. If a remote indoor climate
sensor is included in the scope of delivery, repeat
the procedure for this sensor as well.
Avoid damage:
The climate sensor fits only one of
a certain position into the socket
provided. Make sure that you
insert the plug in the correct
position, otherwise the appliance
may
malfunction
damaged.
9: To complete commissioning, plug the power plug
into the power socket. The unit is then switched on.
ATTENTION
and
be

5. connection of the actuators

The KST-20 Vento climate control system serves as
an intelligent mains switch and can also control
speed-controlled devices. Various connections are
available on the climate control system for this
purpose. Thus, several supply air and exhaust air
elements can be combined with each other and, if
necessary, supplemented by drying or cooling
devices.
The following typical devices can be connected
alternatively or in combination
1-stage ventilation fans (230V AC)
2-stage ventilation fans (230V AC)
Speed controlled fans (0...10V DC)
Motor driven window opener (230V AC)
Ventilation flaps (up to 48V DC)
Drying and cooling units (230V AC)

5.1. Control electronics

Danger to life:
Danger to life from electric shock.
Disconnecting the device from
the power supply.
The KST-20 Vento has 5 terminal blocks (KL).