Calix 2364 ONT Installation Guide
August 2011
#220-00438, Rev. 10

Advertisement

Table of Contents
loading

Summary of Contents for Calix 2364 ONT

  • Page 1 Calix 2364 ONT Installation Guide August 2011 #220-00438, Rev. 10...
  • Page 2 OF SUCH DAMAGES. Calix, Inc. products are not designed or authorized for use as a component in any life support, life safety, or other compa- rable application. Our products should not be used in any application where the failure or faulty performances of the prod- uct might result in a risk of personal injury or death.
  • Page 3: Table Of Contents

    2 2364 ONT Product Overview ........
  • Page 4: Preface

    Network administrators who have experience with communications networks, protocols and equipment. 1.3 Customer Support Calix recognizes the importance of its customers' critical need for uninterrupted service. Post sales technical support is provided to assure a smooth installation and transition to its products and equipment.
  • Page 5: Document Conventions (Safety)

    Warning: This warning symbol alerts you that failure to take or avoid a specific action might result in physical harm to you or to the hardware. Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved..
  • Page 6: 2364 Ont Product Overview

    RJ-45 connector LAN 1: 10/100/1000BaseT port for RJ-45 connector POTS port for RJ-61X connector Grounding lug Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved.. Page 3 of page 38...
  • Page 7: 2364 Ont Interfaces

    2.3.1.2 CON LED 2.3.1.3 ALM (Alarm) LED 2.3.1.4 POTS LEDs 1-4 LED 2.3.1.5 STATUS LED LED 2.3.1.6 Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved.. Page 4 of page 38...
  • Page 8 No alarm condition is present. 2.3.1.5 POTS LEDs 1-4 LED Green Phone is off-hook. Blinking Phone is ringing. Phone is off-hook. Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved.. Page 5 of page 38...
  • Page 9: 2364 Ont Reset Button

    Hold for 0-2 seconds The ONT performs a hard reset. Hold for 2-6 seconds The ONT performs a soft reboot. Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved.. Page 6 of page 38...
  • Page 10: Power Options

    • AUX PWR - input power between +20VDC to +57VDC. This option uses the 2-pin auxiliary connector with 16AWG copper wire. 2.6 Product Specifications Refer to the Calix website (www.calix.com) for product specifications. Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved.. Page 7 of page 38...
  • Page 11: 2364 Ont Installation Steps

    Improper repairs can create a safety hazard Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved.. Page 8 of page 38...
  • Page 12 • The ONT should be located within a region that is less than 25ft from the point of entry of cables entering the physical structure of the building." • The 2364 ONT must be mounted in an area with access to existing customer wiring and grounding. It must be located Proprietary Information: Not for use or disclosure except by written agreement with Calix.
  • Page 13 - If you must mount the 2364 ONT on a dark colored wall, allow a gap of at least half an inch between the ONT and the wall, allowing air to flow behind the ONT and cool the unit. A screen should be placed around the gap to prevent bees, wasps and hornets from building a nest behind the ONT that would obstruct air flow.
  • Page 14: Installing The Ups

    2. Carefully remove the ONT and outer enclosure from the container(s). 3. Examine the units and cables for signs of damage or other mishandling. 4. Check the packing list to verify receipt of all components. Contact Calix immediately to report any discrepancies. 3.4 Installing the UPS Follow the installation instructions that came with the UPS.
  • Page 15: Mounting The 2364 Ont

    3.5.2 3.5.1 Mounting the Outer Enclosure Use the following steps to mount the 2364 ONT outer enclosure. If the electronics panel has been inserted into the outer enclosure, they must be separated prior to installation of the ONT outer enclosure.
  • Page 16 5. Pre-drill the marked locations and install fasteners or anchors appropriate to the mounting surface and the weight of the ON 2364. Please consider that the weight of the 2364 ONT in its enclosure may exceed twenty pounds, depending on your configuration.
  • Page 17: Running Fiber To The 2364 Ont

    The fiber slack management loop in the ONT mold- ing allows up 10 feet of 3mm patch cord or similar size cable to be dressed and secured. Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved..
  • Page 18 1. Install electronics panel by hanging it from the two tabs in the upper part of the enclosure as shown in Figure 3-3. Figure 3-3: Attaching the 2364 ONT Electronics Panel on Hooks Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved..
  • Page 19 NSTALLATION TEPS 2. Attach the bottom of the 2364 ONT panel on the bolt, as shown in Figure 3-4. Figure 3-4: Using the Attachment Bolt on the 2364 ONT Electronics Panel Proprietary Information: Not for use or disclosure except by written agreement with Calix.
  • Page 20 NSTALLATION TEPS 3. Secure the 2364 ONT electronics panel to the enclosure with a 10-32 KEP nut, as shown in Figure 3-5. Figure 3-5: Securing the 2364 ONT Electronics Panel Proprietary Information: Not for use or disclosure except by written agreement with Calix.
  • Page 21: Grounding The 2364 Ont

    To run the ground wire, use the following steps: 1. Terminate a #6 solid copper ground wire into the grounding lug. If you are installing the 2364 ONT electronics panel without the outer enclosure, refer to Figure 3-6 for the location of the grounding lug. If you are installing the outer ONT enclosure refer to Figure 3-7 for the location of the grounding lug.
  • Page 22 2. Route the #6 ground wire at 12" below finished grade by the shortest and most direct route to the Grounding Electrode System at the customer’s premise. Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved..
  • Page 23: Connecting The Power

    • AUX PWR - input power between +20VDC to +57VDC. This option uses a 2-pin auxiliary connector. In this section: Connecting the 7-Pin Power Connector 3.8.1 Connecting the Auxiliary Power 3.8.2 Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved.. Page 20 of page 38...
  • Page 24 2. If necessary, tie wrap both the #6 ground wire and UPS wire run to the buried fiber drop riser conduit. 3.8.1.2 ONT Power Connector The 2364 ONT is provided with a 7-pin conductor socket and plug. There are a two power connectors available: IDC (Insulation Displacement Connector).
  • Page 25 4. Raise the levers on all connections in the IDC plug as shown in Figure 3-9. Figure 3-9: IDC Plug with Connectors Raised Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved..
  • Page 26 Figure 3-12. Figure 3-12: Cut-away View of Connector Fully Seated Inserted into the Conductor Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved.. Page 23 of page 38...
  • Page 27 10. The maximum length of the DC drop is determined by the gauge of the power wire used. The power plug is limited to a maximum gauge of 16AWG. Larger gauges can be supported by compatible lugs. Contact Calix for details.
  • Page 28 Figure 3-15: Auxiliary power +20V to +57V Return Use 16AWG copper wire. Calix recommends a wire insulation strip length of 7mm (0.275"). Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved..
  • Page 29: Connecting The Fiber Optic Cabling

    IBTB (Intersystem Bonding Terminator). The ground bond should not be made to the ground lug inside the ONT. Calix can provide references to acceptable IBTB devices if requested (some are referenced in the “Calix Grounding, Bonding, and Pro- tection Application Note”).
  • Page 30: Connecting Telephone Service (Pots) Wires

    TEPS 3.10 Connecting Telephone Service (POTS) Wires Use the following steps to install the customer-supplied telephone service or POTS wires. The 2364 ONT has four POTS service points which are labeled POTS 1-4. Caution: The 2364 ONT POTS interfaces are designed for intra-building use. Intra-building implies phones within the same structure on which the ONT is mounted.
  • Page 31 Make sure to remove any excess grease on the top panel. Figure 3-17: RJ-61X Connector Pinout (Hook at Back of Connector) Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved..
  • Page 32: Connecting The Ethernet Cables

    1/4 inch diameter into each connector receptacle. Slowly insert an the connector, allowing the grease to well up and fill all the space in the RJ-45 connector and around the Ethernet cable. Make sure to remove any excess grease. Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved..
  • Page 33: Connecting The Ds1 Cables

    RJ-45 connector and around the DS1 cable. Make sure to remove any excess grease. Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved..
  • Page 34: Completing Your Installation

    4. Tighten the captive security hex head screw with the security tool. Do not overtighten it. Installation of the unit is now complete. The unit is ready for service. Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved..
  • Page 35: Safety And Compliance Information

    Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring. Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved. Page 32 of page 38...
  • Page 36 Caution: To reduce risk of fire, use minimum No. 26 AWG Telecommunication Line Cord for data / signaling. Use 22 AWG minimum for power wiring. Caution: Class I LASER Product. Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved. Page 33 of page 38...
  • Page 37 To dispose of them, use the return and recycling systems available in your country. Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved.
  • Page 38 4.2.1 FCC Part 15, Subpart B, Class B The Calix ONT complies with the requirements for Class B digital device per Part 15 of the FCC Rules. Warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
  • Page 39 This Class B digital apparatus complies with Canadian ICES-003. Cette appareil numerique de la classe B est conforme á la norme NMB-003 du Canada. Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved.
  • Page 40: Index

    21 fiber cord 15 ONT 21 fiber splice 15 power LED 4, 5 Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved.. Page 37 of page 38...
  • Page 41 UPS installation 11 WAN LED 5 weatherproofing the ONT 10 WEE compliance 36 Calix 2364 ONT Installation Guide Proprietary Information: Not for use or disclosure except by written agreement with Calix. © Calix. All Rights Reserved.. Page 38 of page 38...