Air System
Requirements
Important: For proper tool performance, air requirements for S75099 should be:
Line Pressure – 100 psi minimum,125 psi maximum (689 – 862 kPa)
Volume - should be 3-5 CFM
Air Delivery system - ¼" minimum diameter airline with a ¼" N.P.T. connection.
Filtration – Follow typical filtration requirements of air operated equipment. Standard filtering
systems should be located no further than 30' from this tool in addition to the
supplemental system supplied at the back of the tool as shown below. This BAND-IT
supplied system includes a filter and lubricator. Lubricator should be refilled with DTE
24 hydraulic oil. The oil drip-rate can be verified by repeated full cycling the tool. One
drop should fall in the sight glass within 10-25 cycles. Excess oil will not benefit tool life
and may lead to blockage of air mufflers and a dirty environment.
Warning:
The lubricator should be refilled with DTE 24 hydraulic
oil only. The use of other oils may cause damage to the system.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street Denver,
CO 80216-3070 USA
P: 1-800-525-0758 F: 1-800-624-3925
View of the back side of the S75099 showing the
supplemental filtering and lubrication system as well as
the ¼" N.P.T. air connection with typical quick connect
coupling.