Download Print this page

ANXELL AXM-800M Series Installation Instruction

Electromagnetic lock

Advertisement

Quick Links

AXM-800M / AXM-D800M / AXM-1200M / AXM-D1200M Series
Electromagnetic Lock Installation Instruction (Indoor Series)
Technical Specification
Specification
Operating Voltage
12/24VDC
500mA/12VDC
Current Draw
270mA/24VDC
Operating
32° to +120.2°F ( 0° to +49°C )
Temperature
800lbs
Holding Force
1200lbs
Lock Surface
Current temperature ± 20°C
Temperature
Humidity
0 to 85% Non-condensing
Magnet Surface : Galvanized
Finish
Housing : Brushed stainless
steel(US32D)
"The products shall not impair the intended operation of an emergency exit or panic hardware mounted on the door."
Dimension & Accessories
AXM-800M
Series
Mounting Plate
29
Magnet
14
Armature Plate
185
29
14
185
45
14
AXM-D800M
Series
AXM-800M
AXM-800MDS
AXM-800MTD
AXM-800MDS-TD
AXM-800M Series
800lbs x2
AXM-1200M Series
AXM-D800M
AXM-D800MDS
AXM-D800MTD
AXM-D800MDS-TD
Anti-tamper Nut
265
52,5
45
Square LED
530
52,5
185
45
Copyright
All rights reserved. P-MU-AM-AXM Published on: 2021.01.29
Model
800lbs
1200lbs
AXM-1200M
AXM-1200MDS
AXM-1200MTD
AXM-1200MDS-TD
1200lbs x2
AXM-D1200M
AXM-D1200MDS
AXM-D1200MTD
AXM-D1200MDS-TD
AXM-1200M
Series
40
16
6
185
40
16
185
61
6
AXM-D1200M
Series
Type
Notes:
M:
M
Bond sensor & Bi-color
square LED indicator
M,DS
DS: Door status sensor
M,TD
TD: Relock time delay
DBL: Double
M,TD,DS
DBL,M
DBL,M,DS
DBL,M,TD
DBL,M,TD,DS
267
61
533
16
185
61
Unit:mm
6
71,5
6
71,5

Advertisement

loading
Need help?

Need help?

Do you have a question about the AXM-800M Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ANXELL AXM-800M Series

  • Page 1 AXM-1200MTD M,TD 32° to +120.2°F ( 0° to +49°C ) TD: Relock time delay Temperature DBL: Double AXM-800MDS-TD AXM-1200MDS-TD M,TD,DS 800lbs AXM-800M Series 800lbs x2 1200lbs x2 Holding Force 1200lbs AXM-1200M Series AXM-D800M AXM-D1200M DBL,M Lock Surface Current temperature ± 20°C...
  • Page 2 Pre-Installation Considerations • Use ONLY the hardware provided for mounting this product (NOTE: Non-standard Door thickness may require different sex nut hardware – see specific instructions for required hardware). • Follow the installation procedure as described in this manual. • Check door thickness. If the door is not 1 3/4” thick, a different sex nut will be required.
  • Page 3 Regular Installation Place the template to the proper position of the door and frame. Fold the mounting template 90°. Mark the hole positions of the template on the door and frame. Please install the armature plate as illustrated here. (Dimensions Drill the holes according to the of the holes depend on the door marks.
  • Page 4 Power Finish Power Protected Area Outdoor Protected Area Outdoor Fasten the Z bracket to the door. Attach the armature plate and washers Close the door and connect the After the magnet attracts the armature to the Z bracket assembly. power. plate, adjust the Z bracket to fit the door.

This manual is also suitable for:

Axm-d800m seriesAxm-1200m seriesAxm-d1200m seriesAxm-800mAxm-800mdsAxm-800mtd ... Show all