Download Print this page
Oriental motor K Series Operating Manual

Oriental motor K Series Operating Manual

Electromagnetic brake motors
Hide thumbs Also See for K Series:

Advertisement

Quick Links

O P E R AT I N G M A N U A L
K Series
Electromagnetic Brake Motors
Introduction
„ Before using the motor
Only qualified personnel should work with the product.
Use the product correctly after thoroughly reading the section "Safety precautions".
Should you require the inspection or repair of internal parts, contact the Oriental
Motor office where you purchased the product.
The product described in this manual has been designed and manufactured for use
as an internal component for general industrial equipment, and must not be used for
any other purpose. Oriental Motor Co., Ltd. is not responsible for any damage caused
through failure to observe this warning.
Safety precautions
The precautions described below are intended to prevent danger or injury to the
user and other personnel through safe, correct use of the product. Use the product
only after carefully reading and fully understanding these instructions.
Handling the product without observing the instructions that
WARNING
accompany a "Warning" symbol may result in serious injury or
death.
Handling the product without observing the instructions that
CAUTION
accompany a "Caution" symbol may result in injury or property
damage.
The items under this heading contain important handling
Note
instructions that the user should observe to ensure safe use of
the product.
• Do not use the product in explosive or corrosive environments, in the presence of
flammable gases, locations subjected to splashing water, or near combustibles.
Doing so may result in fire, electric shock or injury.
• Assign qualified personnel the task of installing, wiring, operating/controlling,
inspecting and troubleshooting the product. Failure to do so may result in fire,
electric shock or injury.
• Do not transport, install the product, perform connections or inspections when
the power is on. Always turn the power off before carrying out these operations.
Failure to do so may result in electric shock.
• Do not use the electromagnetic brake for stopping or for safety purposes. Using it
for purposes other than holding the moving parts and motor in position may cause
injury or damage to equipment.
• Install the motor so as to avoid contact with hands, or ground it to prevent the risk
of electric shock.
• Install the motor in an enclosure in order to prevent electric shock or injury.
• Keep the input-power voltage within the specification to avoid fire and electric
shock.
• Connect the cables securely according to the connection diagram in order to
prevent fire and electric shock.
• Do not forcibly bend, pull or pinch the lead wires (cables). Doing so may result in
fire and electric shock.
• Be sure to insulate the connection terminal of the capacitor. Failure to do so may
result in electric shock.
• Turn off the power in the event of a power failure, or the motor will suddenly start
when the power is restored and may cause injury or damage to equipment.
• Do not touch the connection terminal of the capacitor immediately after the
power is turned off (for a period of 30 seconds). The residual voltage may cause
electric shock.
• Do not disassemble or modify the motor. This may cause electric shock or injury.
• Do not use the motor beyond its specifications, or electric shock, injury or damage
to equipment may result.
• Do not touch the motor during operation or immediately after stopping.
The surface is hot and may cause a skin burn(s).
• Do not hold the motor output shaft or motor lead wires (cables). This may cause
injury.
• Keep the area around the motor free of combustible materials in order to prevent
fire or a skin burn(s).
• To prevent the risk of damage to equipment, leave nothing around the motor that
would obstruct ventilation.
• The motor does not have a built-in overheat protection device. Provide a
protection device externally.
HM-9094-7
WARNING
CAUTION
Thank you for purchasing an Oriental Motor product.
This Operating Manual describes product handling procedures and safety
precautions.
• Please read it thoroughly to ensure safe operation.
• Always keep the manual where it is readily available.
• To prevent bodily injury, do not touch the rotating parts (output shaft, cooling fan)
of the motor during operation.
• When an abnormality is noted, turn off the power immediately, or fire, electric
shock or injury may occur.
• The motor surface temperature may exceed 70 °C (158 °F) even
under normal operating conditions. If the operator is allowed to
approach the running motor, attach a warning label as shown in
the figure in a conspicuous position.
Failure to do so may result in a skin burn(s).
• Dispose the product correctly in accordance with laws and regulations, or
instructions of local governments.
Preparation
„ Checking the product
Verify that the items listed below are included. Report any missing or damaged items
to the branch or sales office from which you purchased the product.
• Motor............................................... 1 unit
• Capacitor ........................................ 1 piece (only for single-phase motors)
• Operating manual ...................... 1 copy (this document)
„ Checking the model name
Check the model number against the number indicated on the product.
Refer to p.2 for the Connection diagram.
z Single-phase motors (Connection diagram: ① )
Output power
Pinion shaft type
2RK6GN-AM
6 W
2RK6GN-CM
3RK15GN-AM
15 W
3RK15GN-CM
4RK25GN-AM
25 W
4RK25GN-CM
5RK40GN-AM
40 W
5RK40GN-CM
z Single-phase motors (Connection diagram: ② )
Output power
Pinion shaft type
5RK60GU-AMF2
60 W
5RK60GU-CMF2
5RK90GU-AMF2
90 W
5RK90GU-CMF2
z Three-phase motors (Connection diagram: ③ )
Output power
Pinion shaft type
15 W
3IK15GN-SM
25 W
4IK25GN-SM
40 W
5IK40GN-SM
z Three-phase motors (Connection diagram: ④ )
Output power
Pinion shaft type
60 W
5IK60GU-SMF2
90 W
5IK90GU-SMF2
Warning label
Model
Round shaft type
2RK6A-AM
2RK6A-CM
3RK15A-AM
3RK15A-CM
4RK25A-AM
4RK25A-CM
5RK40A-AM
5RK40A-CM
Model
Round shaft type
5RK60A-AMF2
5RK60A-CMF2
5RK90A-AMF2
5RK90A-CMF2
Model
Round shaft type
3IK15A-SM
4IK25A-SM
5IK40A-SM
Model
Round shaft type
5IK60A-SMF2
5IK90A-SMF2
1

Advertisement

loading

Summary of Contents for Oriental motor K Series

  • Page 1 • Dispose the product correctly in accordance with laws and regulations, or as an internal component for general industrial equipment, and must not be used for instructions of local governments. any other purpose. Oriental Motor Co., Ltd. is not responsible for any damage caused Preparation through failure to observe this warning.
  • Page 2 „ The rotating direction of the gearhead output shaft may be opposite that of the z Pinion shaft type motor shaft, depending on the gear ratio. Refer to the Oriental Motor Website for Assembling details. Keep the pilot sections of the motor and gearhead „...
  • Page 3 z Single-phase motors (Connection diagram: ② ) z For protection of contact (switch) If the switch is used for starting/stopping the motor or switching the rotation direction, The motor rotates in the clockwise direction if the switch (SW2) is connect the CR circuit for surge suppression in order to protect the contacts. connected to the CW side, and it rotates in the counterclockwise =5 to 200 Ω...
  • Page 4 If the electromagnetic brake is left release, the motor can be started much faster. • Oriental Motor shall not be liable whatsoever for any problems relating to Optimum timing for release of the brake is at least 10 ms before starting up the industrial property rights arising from use of any information, circuit, equipment motor.