Temperature control

Room low temperature
You can set a minimum temperature for when the unit is to stop (Room low temperature).
This function is useful, for instance if you are not in and the heating is cut off. The dwelling is then no longer heated and the room
temperature will fall. To prevent the ventilation unit from cooling the dwelling even further, you can set it to stop at a minimum room
temperature.
Offset ext. heating
If an expansion PCB has been installed, the ventilation unit can control an external heat supply by blocking or releasing external heating
(Offset ext. Heating).
In this way the heat supply and the ventilation unit are able to work together. When no heating is required in the house or when the ven-
tilation unit is in cooling mode, the external heat supply can be blocked.
> Temp. control
> Select heat source
> Rum lav temperatur
> Offset ekst. varme

Supply air control

ATTENTION
The parameters in the menu Supply air control should only be adjusted by persons with knowledge of control
technology.
> Supply air control
> PI regulation
> Integration time
> Neutral zone
> Temperature ramp.
> Capacity ramp.
> Restart time
28
Settings:
Standard setting:
Description:
Settings:
Standard setting:
Description:
Settings:
Standard setting:
Description:
Settings:
Standard setting:
Settings:
Standard setting:
Settings:
Standard setting:
Settings:
Standard setting:
Settings:
Standard setting:
Settings:
Standard setting:
Description:
Off / HP / HP+Afterheat
HP (heat pump)
You can disconnect the heat pump here if you do not want to use
it.
Off / 1  20 °C
Off
Indicate whether you want to stop ventilation at low room
temperatures.
-5  5 °C
-1 °C
Extra heating of the rooms is possible if an expansion PCB has
been installed.
The temperature is added to or subtracted from the setpoint.
0  30%/°
7%/°
0  600 sec.
120 sec
0  10 °C
2 °C
Off / 0.01  10 °C/s
0.10 °C/s
Off /0.10  10.0%/s
0.5%/s
0  60 minutes
6 minutes
Minimum duration (in minutes) for which the compressor has to
be off before it restarts.