 1. Cyclone Assembly
o The cyclone assembly uses cyclonic action in order to
separate the bulk product from the air-stream.
o It is found bolted to the shipping rack separate from
other parts.
o The cyclone assembly bolts to the airlock package.
 2. Receiver Midsection
The receiver midsection holds the four filters used to
o
further separate bulk product from the
airstream.
The receiver midsection is the portion of
o
the receiver that is to bolted to the Cyclone
Assembly.
Install with care, ensuring there is no
o
damage to the explosion vent.
 3. Receiver Top
o The receiver top is the portion of the machine that
controls the air-purge cycle. It uses high
pressure air to clean the filters in the
midsection.
o The receiver includes purge valves, an air
tank and a timer control box attached to it.
o The receiver top comes pre-assembled
with the receiver midsection.
R-1: March 17, 2018
Fig 1. Cyclone Assembly
Fig 2. Receiver Midsection
Fig 3. Receiver Top