  • Page 1 OPERATOR’S MANUAL DROP-THROUGH ROTARY AIRLOCKS MODELS: AL 1314 , AL 1618 , AL 2224...
  • Page 3: Technical Support

    Dear Customer, Thank you for choosing WALINGA PNEUMATIC CONVEYING SYSTEMS. For your convenience, should you require any information related to Parts, Service or Technical Engineering, please contact one of the following Walinga Personnel in Guelph at 1-888 925-4642 unless noted*...
  • Page 4: Table Of Contents

    Walinga Rotary Airlock Operator's Manual Model AL 1314 , AL 1618 , AL 2224 -TABLE OF CONTENTS – SECTION DESCRIPTION PAGE Technical Support…………………………… INTRODUCTION………………………………… Principle of Operation …………………………… Airlocks & Rotary Seals ………………………… KEY OPERATING GUIDELINES………………. Direction of Rotation……………………………… Tip Clearances…………………………………….
  • Page 5: Introduction

    WEAR RATES IN THE CASING AND LOSS OF 1.1 Operating Principles PERFORMANCE. Walinga Rotary Airlocks use a multi-bladed rotor to move material. The rotor picks up Operating for short periods in reverse direction is material in the pocket between each 2 blades acceptable but only to assist in clearing objects as it rotates past the top feed inlet area.
  • Page 6: Flexible Tip Wiper

    2.4 Flexible Tip Wiper (If applicable) housed in a sealed housing. The housing must remain sealed and slightly lubricated to prevent The intake chamber has a flexible tip wiper corrosion that will prevent these bearings from bolted to the left hand side (viewed from the floating.
  • Page 7: Troubleshooting

    4 TROUBLESHOOTING The Walinga airlock delivers long periods of trouble-free operation when operated and serviced correctly. This trouble-shooting guide will help identify and solve operating problems if they occur. WARNING - ISOLATE THE AIRLOCK FROM YOUR POWER SUPPLY BEFORE CLEARING OR ADJUSTING Operating Problem Possible Cause &...
  • Page 8: Air Blow-Back Restricts Feed Inlet

    Operating Problem Possible Cause & Recommended Action 4.2.2 Prolonged Operation in The Walinga airlock operates in an counter-clockwise direction Reverse Direction when viewed from driven end. Damage to rotor blades and tips due to prolonged operation in the opposite direction may cause jamming.
  • Page 9: Airlock Maintenance

    Note:Tip Retaining Screws, Shim Metal Spring & • Permanent Marker Pen Washers are available from Walinga Inc. casing – bottom ports on Blow- 5.2 Replacing Damaged Blade Tips Thru units are a convenient removal point. If one edge of an airlock blade tip is damaged it...
  • Page 10: Adjusting Tip Clearances

    5.3 Adjusting Tip Clearances 5.4 Out-Of-Round Casing Wear Place an identifying number on the leading An airlock that has excessive out-of-round side of the first blade e.g .. #1'. This is wear in casing will operate poorly. Airlocks important - it is easy to miss a tip unless wear rate and out-of-round wear increase every blade is marked as it is adjusted.
  • Page 12: Rotary Airlock Components

    6.1 ROTARY AIRLOCK MODEL AL 1314 COMPONENTS...
  • Page 13 6.1 ROTARY AIRLOCK MODEL AL 1314 COMPONENTS CONT’D...
  • Page 14: A/L 1618

    6.2 ROTARY AIRLOCK MODEL AL 1618 COMPONENTS...
  • Page 15 6.2 ROTARY AIRLOCK MODEL AL 1618 COMPONENTS CONT’D...
  • Page 16: A/L 2224

    6.3 ROTARY AIRLOCK MODEL AL 2224 COMPONENTS...
  • Page 17 6.3 ROTARY AIRLOCK MODEL AL 2224 COMPONENTS CONT’D...
  • Page 18 CORPORATE HEAD OFFICE: RR#5 Guelph, Ontario, N1H 6J2 PHONE (888) 925-4642 FAX (519) 824-5651 www.walinga.com FACTORY DISTRIBUTION AND SERVICE CENTRES: 1190 Electric Ave. Wayland, MI.USA 49348 Tel (800) 466-1197 Fax (616) 877-3474 938 Glengarry Cres. Fergus, Ontario Canada N1M 2W7...