Error Detection And Indication - TCS FBO1100-0400 Product Information

Interface for tk systems
Table of Contents

Advertisement

04/2013
 First, eliminate the following errors:
acknowledgement, description
"The called" is busy: acknowledgement after calling a stored num-
ber, if the called client is busy (audible at the front-door station).
Unsuccessful call: acknowledgement after calling a stored number, if
the called client is not accepting within a period of time (audible at
the front-door station).
"Dialing register empty": acknowledgement as reaction to pressing a
bell button, if no call number is entered in the dialing register (audi-
ble at the front-door station).
 Then check the system for errors.

Error detection and indication

Errors are signaled optically and acoustically:
 After the call at the FBO1100 an error tone sounds for three times (audible at the tele-
phone), then the connection is disconnected.
 The red LED at the TK-Interface blinks or flashes permanently (see table below).
 The optical error indication at the TK-Interface stays active until the error is corrected.
error causes
TCS:BUS is busy
a- and P-wire
interchanged or short-circuited
BUS error a:
a-wire is not connected or not
supplied
variant error*
TK-Interface has a different vari-
ant, as an already connected one
but the same block number
block number error*
TK-Interface has the same vari-
ant and the same block number,
as an already connected one
* The SN20 bit-function is moved to an invalid area for the TK-Interface (SN 2044, BlNr 128).
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88
FAX: +49 (0) 41 94/ 9 88 129  Mail: hotline@tcsag.de
11
yellow
error
red LED
LED
tone
blinks
OFF
slowly
flashes
OFF
blinks
ON
fast
flashes
twice,
OFF
long
break
flashes
three
times,
OFF
long
break
acoustic
reaction
description, solution
Acknowledgement after calling the
FBO1100, if a voice connection is acti-
vated at the TCS:BUS or an alerting or
announcement is running (audible at
the telephone)
 After a timeout of 5 min the status
must be finished
Every 2 min, the system is checked if
the error still exists.
 exchange a- and P-wire or eliminate
short-circuit, device is in stand-by
mode again
 connect the a-wire or check mains
connection, device is in stand-by
mode again
 press the Reset button
 change the block number of the
FBO1100 to another value
 press the Reset button
 change the block number of the
FBO1100 to another value
Subject to technical changes.
PI_FBO1100_uk 1A
optical
reaction
yellow LED
blinks fast
yellow LED
blinks fast
yellow LED
blinks fast