With suitable measures to protect against lightning, it has to be ensured that a voltage of each 32 V DC is not exceeded at the connections. TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes.
FBO1100 and FBO1200 must not be connected simultaneously to a TCS:BUS! Note: If there is more than FBO1200 connected to a TCS:BUS, this error is signalled by the red LED (flashes three times, long break, see also Error detection and indication, page 10 ).
The FBO1200 is connected to the PBX / PSTN just like an analogue telephone. The FBO1200 needs a TCS:BUS, that at least consists of power supply and control unit and a front-door station. Alternatively, also indoor stations can use the FBO1200 as interface.
04/2013 Commissioning steps Install the devices of the TCS system completely and connect the FBO1200 to the tele- phone system (see wiring example). Check the a-, b- and P-wire against each other on short-circuits. Switch on the mains voltage.
TK-Interface and power supply and control unit * in Zusammenhang mit Konfiguration der Außenstation TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes. FAX: +49 (0) 41 94/ 9 88 129 Mail: hotline@tcsag.de...
0=OFF 1=ON Controlling the switch-off tone while calling a front-door station TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes. FAX: +49 (0) 41 94/ 9 88 129 Mail: hotline@tcsag.de...
Page 13
The max. permitted loop resistance between TK-Interface and power supply and control unit (1 not possible with BVS20) TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes. FAX: +49 (0) 41 94/ 9 88 129 Mail: hotline@tcsag.de...
Release the button Reload factory settings. The factory settings are reloaded. The pro- cess takes around 2 s. During this time the actuator output is active. TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes.