Panasonic KX-TG6671B Service Manual page 37

Digital corded/cordless answering system
Hide thumbs Also See for KX-TG6671B:
Table of Contents

Advertisement

10.1.5.2. Portable
Does Portable make link with Base Unit?
(Correct working unit)
NO
Is the voltage of TP VBAT about 2.2~2.8 V?
YES
Is the voltage of TP VDDC about 1.2 V?
YES
Is the voltage of TP 3.0 V about 3.0 V?
YES
Does the RF clock (CLK) oscillate: 13.824 MHz
in Portable Test Mode?
YES
Check the RF part
Cross Reference:
Power Supply Circuit/Reset Circuit (P.19)
Check the RF part (P.38)
Note:
*1 How to adjust +3.0V:
Execute the command "VDA"
Refer to Things to Do after Replacing IC or X'tal (P.60) for Portable.
*2 How to adjust the frequency of X1:
To see the frequency, execute the command "SFR", then check the TP_CKM (IC1-57pin).
To adjust frequency, send command "SFR
YES
Portable is OK. Check Base Unit.
NO
Check the batteries.
NO
Check around Power Supply Circuit/Reset Circuit.
OR
Adjust +3.0V Vottage to 3.0V
NO
Check around X1 and RF module and adjust
clock frequency.
"until the frequency counter becomes13.824 MHz±55HZ.
37
KX-TG6671B/KX-TG6672B/KX-TGA660B
*1
*2

Hide quick links: