used will be displayed as below. Once the deferral expires, the alarm will sound once again. The
deferral can be repeated up to three times. PLEASE NOTE: At any point after lamp expiration,
the water may be unsafe for consumption and should not be consumed without another form
of disinfection.
System Service Suggested
UV5 & UV6 controllers will display the System Service Suggested Screen
every 6 months to remind consumers to maintain both their UV and other
prefiltration. This will serve as a prompt only and will not put the system
into alarm. To clear this condition simply press the button located below
the screen.
Lamp Replacement (UV4 systems)
After the lamp is expired, it must be replaced with the same part number as indicated by the
label on the reactor. Begin replacing the lamp by unplugging the power for the controller, then
refer to Installation (page 11) for instructions on installing the new lamp. To reset the timer in
the controller, firmly hold down the button on the controller for 10 seconds. The controller will
read "rSt3", "rSt2", "rSt1" and then beep. The button can now be released, the lamp countdown
timer has been reset.
Lamp Replacement (UV5 & UV6 systems)
After the lamp is expired, it must be replaced with the same part number as indicated on the
Maintenance Parts screen or on the label on the reactor. With the system powered down,
remove and discard the lamp key from the controller. The replacement lamp is packaged with
a lamp key on the connector at the end of the lamp. Remove the key from the lamp and place
it in the controller. Refer to Installation (page 11) for instructions on installing the new lamp.
QR Codes (UV5 & UV6 systems)
QR codes store a link to a specific page on our website. Users with a camera
phone equipped with the correct reader application can scan the image
of the QR code and over a wireless network connect to a SpringWell web
page in the phone's browser. The QR webpage has information on how to
purchase replacement components as well as a helpful video directory on
system servicing (i.e. How to change a UV lamp or quartz sleeve). To access
the QR code on the controller, press the control button until the QR code
screen appears.