Part No. 70-7100 (Rev A)
Operation and Maintenance Manual
120R Rocking Piston
Oil-less Air Compressor
A UNIT OF IDEX CORPORATION
www.gastmfg.com
ISO 9001 CERTIFIED
® Registered Trademark/™ Trademark of Gast Manufacturing Inc. ©Copyright 2021 Gast Manufacturing Inc. All Rights Reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 120R and is the answer not in the manual?

Questions and answers

Summary of Contents for Gast 120R

  • Page 1 Part No. 70-7100 (Rev A) Operation and Maintenance Manual 120R Rocking Piston Oil-less Air Compressor A UNIT OF IDEX CORPORATION www.gastmfg.com ISO 9001 CERTIFIED ® Registered Trademark/™ Trademark of Gast Manufacturing Inc. ©Copyright 2021 Gast Manufacturing Inc. All Rights Reserved.
  • Page 2: Table Of Contents

    Part No. 70-7100 (Rev. A) Dear Customer: Thank you for purchasing this Gast product. It is manufactured to the highest standards using quality materials. Please follow all recommended maintenance, operational, and safety instructions and you will receive years of trouble free service.
  • Page 3: Product Use Criteria, And Purpose

    . Disconnect electrical power at the circuit breaker or fuse box before installing this product. • Consult your Gast Distributor/Representative before using at high altitudes . Install this product where it will not encounter water or other liquids.
  • Page 4: Mounting

    The product’s external intake and exhaust muffler will provide adequate filtration in most applications . Check filters periodically and replace when necessary . Consult your Gast Distributor/ Representative for additional filter recommendations . Install relief valves and gauges at inlet or outlet or both, to monitor performance .
  • Page 5: Extension Cords

    . 8-10 10-12 12-14 14-16 16-18 18-20 © 2021, Gast Manufacturing We reserve the right to make any alterations which may be due to any technical improvements Printed in the USA...
  • Page 6: Maintenance

    Proper shutdown procedures must be followed to prevent pump damage . Failure to do so may result in premature pump failure . Gast Manufacturing Rocking Piston Oil-Less Pumps are constructed of ferrous metals or aluminum which are subject to rust and corrosion when pumping condensable vapors such as water .
  • Page 7 Part No. 70-7100 (Rev. A) Gast offers the following Service Kits for the 120R compressor . Description Kit Number Service Interval 120R Preventative Maintenance Kit K1027 1000 hours or one year 120R Service Kit K1028 6000 hours or five years...
  • Page 8: Parts And Ordering Information

    Part No. 70-7100 (Rev. A) EXPLODED PRODUCT VIEW © 2021, Gast Manufacturing We reserve the right to make any alterations which may be due to any technical improvements Printed in the USA...
  • Page 9: Troubleshooting Chart

    Motor not wired correctly – check Ò Ò wiring diagram/line voltage SERVICE AND MAINTENANCE CHART Date Problem Technician Notes © 2021, Gast Manufacturing We reserve the right to make any alterations which may be due to any technical improvements Printed in the USA...
  • Page 10: Warranty Policy

    Gast Manufacturing Incorporated, PO Box 97, Benton Harbor Michigan USA 49023-0097 or an authorized Service Center (unless specif- ically agreed upon in writing signed by both parties or specified in writing as part of a Gast OEM Quotation). Buyer is responsible for freight charges both to and from Gast in all cases.