Download Print this page

Adaptec ICP5045BL Supplementary Manual page 5

Adaptec icp5045bl serial controllers: supplementary guide
Hide thumbs Also See for ICP5045BL:

Advertisement

o
135 MB hard disk drive space
o
256 color video mode
2.3 General Setup Notes
- Do NOT attempt to install ICP Storage Manager version 5.01
on a system that already has ICP Storage Manager version
4.x installed.
- You can configure ICP Storage Manager settings on other
servers exactly as they are configured on one server.
replicate the ICP Storage Manager tree and notification list,
do the following:
1.
Install ICP Storage Manager on one server.
2.
Start ICP Storage Manager. Using the 'Add remote system'
action, define the servers for your tree.
3.
Open the Notification Manager. Using the 'Add system'
action, define the notification list.
4.
Exit ICP Storage Manager.
5.
Copy the following files onto a diskette from the directory
where the ICP Storage Manager is installed:
RaidMSys.ser --> to replicate the tree
RaidNLst.ser --> to replicate the notification list
RaidJob.ser
6.
Install ICP Storage Manager on the other servers.
7.
Copy the files from the diskette into the directory where
ICP Storage Manager is installed on the other servers.
- ICP Storage Manager can monitor status information returned
from certain enclosures. If there are any problems, information
such as fan status, power supply status, and temperature status
is collected and reported in the event viewer.
To monitor an enclosure, do the following:
1.
Write down the description displayed in the 'Product or
Model Number' field of the enclosure device information panel.
2.
Exit ICP Storage Manager.
3.
Using a text editor, open the RaidDev.pps file. This file
is in the directory where ICP Storage Manager is
installed.
4.
Using the enclosure description from step 1, add a line to
the file. For example, if the description is 3520EX10, add
the following:
3520EX10=true
--> to replicate the jobs in the Task Scheduler
To

Advertisement

loading